HEATING INSTALLATION INSTRUCTIONS
CEILING & WALL MOUNTING BRACKETS
1. Heater must be installed with the minimum installation
clearances shown in diagram.
Minimum distance between heaters measured from
edge of heaters must be at least 500mm.
WALL MOUNTING
CEILING
!
WARNING
This heater MUST be permanently installed by
an authorised/licenced person. Do not perform
maintenance, or carry out installation or assembly
procedure while electrical power is switched on.
8
All manuals and user guides at all-guides.com
FLOOR
www.bromicheating.com
Minimum distance from edge of the heater to any
adjacent walls must be at least 250mm. Heater must be
away from the fourth wall.
During installation the supply cord should be
positioned such that it exits from the nearest edge
of the heater and not from the centre or across the
heater.

CEILING MOUNTING

CEILING
250
!
WARNING - Outdoor Installation
For longest product life & to maintain product
appearance mount heater under cover & protect
from rain & weather whenever possible.