TROUBLE SHOOTING

Problem:
Burner will not light
Fire at control knob
Yellow Flames at burner
Flame blows out on "LOW"
Grill is Too Hot
Possible Causes:
1. Check natural gas supply.
2. Bad electrode spark.
Check to see if the grill will match light.
Electrode or collector may need adjustment.
3. Burner may not be properly seated.
4. Burner may be obstructed.
1. Burner holes may be obstructed. See section on
"Burner Assembly/Maintenance" under Proper Care
and Maintenance.
2. Burner is improperly seated on control valve.
3. Gas connections may be loose.
Leak Check and tighten all connections.
1. Burner is obstructed. See section on
"Burner Assembly/Maintenance" under Proper Care
and Maintenance.
1. Burner holes may be obstructed. See section on
"Burner Assembly/Maintenance" under Proper Care
and Maintenance.
2. Grill is not sufficiently preheated.
3. Burner is improperly seated on control valve.
1. Excess grease build-up causing grease fires.
2. Cook on a lower temperature setting.