Getting Started; Tools And Parts Required; Important Installation Instructions - 3M Aqua-Pure AP200 Manual Del Usuario

Ocultar thumbs Ver también para Aqua-Pure AP200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

All manuals and user guides at all-guides.com
Your new Aqua-Pure
®
AP200 Drinking Water System will reduce chlorine taste and odor, and sediment from your drink-
ing water. The system installs under the sink on the cold water line. The installation procedure covered in this manual
requires the removal of a section of the cold water tube. Soft copper tubing and compression fittings should be pur-
chased locally to complete the installation.
Parts and Materials Included:
1. Mounting Bracket
2. Two Mounting Screws, Four Washers,
Two Nuts, And Two Self-tapping Screws
3. System Head
4. Sump
5. AP217 Cartridge

Tools and Parts Required

(not included):
• Two 3/8" Pipe Thread Male Connectors
• Compression Fittings
• 3/8" Soft Copper Tubing
• Drill (Cordless Recommended)
• Adjustable Wrench
• Phillips Head Screwdriver
• Razor Knife Or Tube Cutter
• PTFE Tape
• Silicone based lubricant
Empty contents of package and identify all parts as
shown in diagram. Read all instructions carefully
before attempting to start installation. The existing
shut-off valve remains in place and still acts as the
cold water shut-off.

IMPORTANT INSTALLATION INSTRUCTIONS

1. Position the filter by holding it against the side of the cabinet wall underneath
the sink. Allow at least 7 1/2" beneath the filter to install cartridge. Determine
a desirable location for the filter installation and inlet connection. Attach the
mounting bracket to appropriate mounting bosses on filter head with the self-
tapping screws. (Figure 1)
2. Remove drawer from cabinet (if needed) and drill two 7/32" diameter holes
through cabinet wall. Fasten filter to wall with nuts and bolts supplied. Use
washers on both sides of the wall. Mounting to the cabinet side wall gives the
filter good, rigid support. (Figure 2)
To reduce the risk associated with a hazardous voltage due to an
installer drilling through existing electric wiring or water pipes in the
area of installation:
• Do not install near electric wiring or piping which may be in the path of
a drilling tool when selecting the position to mount the filter bracket.
To reduce the risk of property damage due to water leakage:
• Install on COLD water lines only.
• Mount filter in such a position as to prevent it from being struck by
other items.
• Do not install near water pipes which will be in path of a drilling tool
when selecting the position to mount the bracket.
IMPORTANT NOTES
• Allow a minimum of 7 1/2" (19.5 cm) clear space under filter to facilitate
cartridge change.

GETTING STARTED

WARNING
CAUTION
1
3
4
7 1/2"
Figure 1
Cabinet
Side Wall
Screws
Figure 2
2
5
Washers
Nuts
Washers

Publicidad

Tabla de contenido
loading

Tabla de contenido