Internal Parameter Setting
Press-n-hold on [Mode] key to start the setting
Press [Mode] to advance to the next item
Press [▲] / [▼] to adjust the value
Press [blank] key to confirm and exit
Items
Value
Default
Value
User Interface
0-3
Screen Saver
(P00)
Screen Saver
0-120
Count down (P01)
Display unit (P02)
°C / °F
°C
Time Display unit
12 /24
(P03)
Temperature
-5°C ~ 5°C,
0°C
Offset (P04)
-10°F ~ 10°F
Switching
2 ~ 4°C, 4 ~ 8°F
2°C
Differential Heat
(P05)
Switching
2 ~ 4°C, 4 ~ 8°F
2°C
Differential Cool
(P06)
Program mode
No program (0) /
(P07)
1day program (1)/
5+1+1 program (2)
/ 7day program (3)
Adaptive Control
Enable / Disable
Disable
(P08)
System Mode
Heat / Cool
Heat
(P09)
Sensor Mode
Internal Sensor /
Internal
(P10)
External Sensor /
Sensor
Combined mode
Floor temperature
20-40°C, 68-104°F
40°C
limit (P11)
User Interface Screen Saver:
The thermostat will go to screen saver mode after no
3: 7day prog 3: 7day program, The thermostat control the
key for certain period
Mode 0: Nothing will be displayed in screen saver
mode.
Mode 1: Only room temperature will be displayed in
screen saver mode.
Mode 2: Room temperature and Time will be
displayed in screen saver mode.
Mode 3: Display all in screen saver mode.
Screen Saver Count Down:
The count down time (in seconds) to screen saver
mode.
Display Unit:
Temperature unit in Celsius or Fahrenheit.
Time Display Unit
12/24.
Temperature offset
The temperature of internal sensor can be calibrated
from -5°C - +5°C in case there is temperature
difference between actual value and thermostat.
Switching Differential
The difference between switching the heating or
0
controller on and off
20
12
3
Program Mode:
0: No Program Mode, The thermostat control the
temperature simply according to single setpoint.
1: 1 day program, The thermostat control the
temperature according to single schedule.
2: 5+1+1 day program, The thermostat control the
temperature according to 5 +1+1 schedule (Mon to
Fri, Sat, Sun).
temperature according to 7day program (individual
program for each day).
Adaptive control
When this function is enable, the thermostat learns
the time taken to reach the desired setpoint and turn
on the heating / cooling earlier so that the room
temperature will reach the setpoint at desired
schedule. This is no effect when No program is
selected.
Heat / Cool Mode
When Heat mode is selected, the thermostat control
The room temperature with heating. Room Sensor,
Floor Sensor or Combined sensor can be selected.
When Cool mode is selected, the thermostat control
The room temperature with cooling. Only room
Sensor, will be used.
Sensor Mode
There are 3 different settings of sensor control for
Heat Mode. (For Cool Mode. Only Room sensor will
be used)
- Room sensor
Thermostat control the room temperature based on
Room Sensor
- Floor sensor
Thermostat controla the room temperature based on
Floor Sensor
-Combined Floor/Room sensor
Thermostat control the room temperature based on
Room Sensor. And the output will be off if floor
temperature above "floor temperature limited" for
protection.
Floor temperature limited
It is the temperature limited for floor sensor. When the
Heat Mode and Combined Sensor are selected. The
output will turn off when floor sensor senses the
temperature higher than the floor temperature limit.
Advanced – Factory Default
Items
Value
Clear Wifi Configuration
Yes or No
(P19)
Clear Parameter setting
Yes or No
(restore default) (P20)
Press-n-Hold on [Mode]+[Fan] keys
Press [Mode] to advance to the next item
Press [▲] / [▼] to adjust the value
Press [blank] key to confirm and exit
Clear Wi-Fi Configuration (P19):
When set to yes, the SSID and Password stored in
the thermostat will be cleared
Clear Parameter setting (P20):
When set to yes, all Internal parameter settings will be
restored to default value in next power on i.e.
power-cycle needed to complete the clearing.
Defrost
When the room temperature is below 5
o
C / 41
output will turn On at Heat mode or output will turn off
at Cool mode. "
"defrost indicator appears on the
screen.
Minimum off time
The minimum off time for Heat mode is 5 seconds
and 4 minutes for Cool mode.
Technical Data
1.
Power supply:
230 ± 10% V
Relay Contact Voltage:
230V
Relay Contact Current:
16A max
Sensing Element:
103AT
Terminals:
2 sq. mm Cable
32 – 122 °F / 0 – 50 °C
Operating Temperature:
23 – 122 °F / -5 – 50 °C
Storage Temperature:
Operating Humidity:
5-95%RHnon-condensing