MAINTENANCE
Draining water from your air cooler at the
A
end of the summer season is not required if
your cooler is fitted with an automatic drain
valve. However, it is advisable to check the
pump, drain valve, solenoid and fan motor
every 2 years. If the alternative bleed
system is installed then maintenance
should be conducted before and after the
summer season as outlined below.
WARNING: We recommend maintenance is
carried out by an authorised service agent.
Climbing onto the roof is hazardous and
can result in personal injury or property
damage. Power to the cooler must be
disconnected before pad frames are
B
removed or you may risk personal injury.
HEALTH REGULATIONS
Note that some regulating authorities
require services to be conducted at specific
intervals.
END OF SEASON SERVICE
• Turn off the power supply to the cooler.
• Turn off the water supply to the cooler.
• Remove the pad frames as shown.
• A. Turn off the power switch inside the
cooler.
• B. Check and clean the lid water channels
• C. If fitted, first unclip and then remove the
C
bleed system as shown. Allow the tank
water to drain. Do not re-fit the bleed
system at the end of the season. Do not to
lose the o-ring.
• Thoroughly clean the tank and pump filter.
• Re-fit the pad frames.