technical parameters.
If the unit stops supplying air for any reason, the user must leave the contaminated area immediately.
When combined with a welding helmet, safety helmet or with a mask, the unit is not recommended for users
with a beard or long hair extending to the respiratory zone.
Beware of a higher CO
properly when the lubricating oil sometimes burns due to high temperatures.
The supply air pressure must be in the range between 400 - 1000 kPa.
The air source must be equipped with a safety valve to guarantee that the inlet pressure will be not exceeded.
The supply pressure hoses may only be located in such areas of the workplace where they cannot be damaged.
Pressure hoses for suppliedair and suppliedair Conditioner, order No. 4090.050 and 4090.051, are not antistat-
ic and the maximum temperature to which they are resistant without damage is 70 °C.
The maximum length of the pressure hose from the compressed air distribution or suppliedair Conditioner to
the unit must not exceed 10 m; this only applies for combinations of products with level of protection 1A - 4A.
For combinations of products in the class 1B - 4B, the length of supply hose is unlimited.
The recommended temperature range of use is 10 - 40 °C; at lower temperatures, use of the protective hood
or mask with air supply may be unpleasant.
For the suppliedair it is necessary to provide breathable air according to EN 12021.
The suppliedair can be combined with the types of head parts shown on page 2 of the manual. It also shows
the classes for the respective combinations.
Information on head parts is provided in the instructions on using the suppliedair head parts
If any principle stated in this manual is not followed, the warranty becomes null and void!
3. Unpacking / Assembly / Use and Functions
3.1.
Unpacking the suppliedair
Check that the delivery is complete and no damage occurred during the transport.
Contents of the suppliedair (4090.000), suppliedair (4090.010):
suppliedair unit
Belt for the unit
Air hose
Air flow indicator
User manual
Contents of the suppliedair Conditioner (4090.100):
suppliedair Conditioner unit
Unit stand
Screws for connecting the unit to the stand
Gasket
Instruction for Use
3.2.
Assembling the suppliedair Conditioner (4090.100)
Screw the container (suppliedair Conditioner) down onto the stand; for the procedure see pictorial annex.
3.3.
Assembly - suppliedair
Check that all components are in good condition, i.e. without apparent damage.
Connect suppliedair Conditioner to the compressed air distribution system or straight to a compressor. If the
suppliedair Conditioner is not used, the compressed air supply is connected straight to the suppliedair.
Attach the unit onto your belt and connect the pressure hose to it.
Using the quick coupling, connect the pressure hose from the compressed air source to the suppliedair unit.

4. Before Use

concentration in the air supply, which may occur if the compressor does not work
2
1 pc
1 pc
1 pc
1 pc
1 pc
1 pc
1 pc
2 pcs
4 pcs
1 pc
5