Parameters
A
current water temperature at inlet
C
current temperature at heat exchanger
The heat pump has eight adjustable parameters:
Parameters
1
desired water temperature
2
Temperature difference for restart
4
Automatic restart
5
Duration for automatic defrost function
6
Temperature setting for automatic defrost function
7
Temperature setting for exiting automatic defrosting
8
Exit automatic defrosting

Operation

Risk of death when operating the water treatment system during bathing.
Hair or clothing might get sucked into the suction openings of the pool and in extreme cases
trap persons under water and prevent them from surfacing again.
- Never operate water treatment system devices while persons are in the pool.
- Prevent any access to the pool for as long as water treatment system devices are in use.
A damaged device or damaged accessories may cause injuries.
- Check the device and the accessories (see section "Testing").
Reduced or blocked ventilation of the heat pump can lead to faulty extraction of heat or
moisture. This might cause mold or overheating of the finned heat exchanger.
- Clean the grate in front of the fan impeller and the fins of the heat exchanger at regular
intervals and make sure that dirt such as leaves or similar does not get into the heat
exchanger.
- Make sure that the grate on the heat exchanger is never covered up and that the air can
circulate freely through the device.

RCD power plug

The RCD power plug consists of a safety plug and a residual current circuit breaker. The safety plug
must be connected to a matching socket with an earthed protective conductor. The residual current
circuit breaker disconnects the heat pump from the voltage as soon as unexpectedly high currents that
are dangerous for persons flow through the heat pump (e.g. short circuit through electroconductive parts
of the housing).
Display range
-19 °C to +99 °C
-19 °C to +99 °C
Setting range
15 °C to 35 °C
1 °C to 10 °C
0 to 1
10 min to 90 min
-30 °C to 0 °C
1 °C to 30 °C
10 min to 40 min
WARNING!
CAUTION!
Risk of injury!
NOTICE!
Example
A 25 (25 °C)
C 9 (9 °C)
Default
1 27 (27 °C)
2 2 (2 °C)
4 1 (1 °C)
5 40 (40 min)
6 0 (0 °C)
7 2 (2 °C)
8 30 (30 min)