The desired value of the selected parameter blinks on the display
2. Press the SET button
The desired value of the selected parameter is set.
Deinstallation
Risk of injury when moving heavy equipment!
The device is heavy! Incorrect lifting or uncontrolled toppling of the device can lead to injuries
or damage the device.
- Always carry or tilt the device with the help of at least one other person, never alone.
- Make sure that your posture is correct (straight back, secure footing, etc.).
- Use transport aids (such as a lifting truck or roller board).
- Wear protective equipment, such as safety shoes or gloves.
Disconnecting the lines/pipes
Disconnecting the power supply
1. Put the heat pump into standby mode (see section "Display").
2. Press the RESET
12
3. Disconnect the RCD power plug
The heat pump is disconnected from the power supply.
Disconnecting the water lines
1. Deactivate the water treatment pump.
2. Undo the hose clamps
3. Pull the hose end off the adapter
When removing the hose end of the water line, hold it with the opening facing upward so that
residual water in the hose does not uncontrollably run out.
4. Unscrew the hose end from the adapter
When removing the hose end of the water line, hold it with the opening facing upward so that
residual water in the hose does not uncontrollably run out.
The water lines are disconnected.
Cleaning
Cleaning the device
Wipe the surface with a dry cloth.
Test
Check the following before each use:
- Is there visible damage on the device?
- Is there visible damage on the control elements?
- Are the accessories in flawless condition?
- Are all lines in flawless condition?
- Are the ventilation slots unobstructed and clean?
Do not start up a damaged device or damaged accessories. Have them checked by the manufacturer or
its customer service or a qualified service technician.
.
18
CAUTION!
button.
from the power supply.
C
on the adapters
.
3
2
at the inlet water connection
2
at the outlet water connection
2
.
14
.
7
.
6
39