Calibration Adjustment

See graphics: wc_gr004603 and wc_gr004604
2
3.3.1
Make new "A" and "B" marks as directed in "Checking Calibration."
Make a third mark halfway between the new A and B. Call this mark
"C." This is the correct beam center.
3.3.2
The calibration port for each axis is located on the top front of the laser.
Choose the X axis port (2) or the Y axis port (3) as necessary. Open
only one cover at a time to avoid adjusting the wrong axis.
3.3.3
Using a small screwdriver, carefully turn the exposed calibration port
adjustment screw left or right until the beam is centered at mark C.
Make adjustments in small, careful increments. After each adjustment,
check beam movement at the pole.
3.3.4
Double check the axis. Rotate the laser 180° and again check the
beam. The beam should now strike within 1/16" (1.5 mm) of mark C. If
not, repeat steps 1–3, adjusting as needed until the axis is calibrated.
3.3.5
Check and adjust the calibration of the other axis. Calibration is
complete when mark C is the same for both axes in both directions.
wc_tx000807gb.fm