INSTRUCTIONS FOR USE
RADIATOR FILLER
LIST OF PARTS:
DESCRIPTION
1
GAUGE
2
FIXING HOOK
3
TAP
4
AIR FITTING
5
"ON –OFF" BUTTON
6
TAP
7
RADIATOR CAP FITTING
8
RADIATOR COOLANT HOSE FITTING
9
UNIVERSAL RADIATOR CAP
10
RADIATOR COOLANT HOSE
CAUTION: OPERATE WITH COLD ENGINE TO AVOID BURNS.
OPERATING INSTRUCTIONS:
SYSTEM EMPTYING AND BLEEDING
1. THOROUGHLY DRAIN THE COOLANT OUT OF THE RADIATOR.
2. FIX THE INSTRUMENT TO THE BONNET BY MEANS OF THE SUPPLIED CHAINS.
3. CONNECT TO THE RADIATOR THROUGH THE UNIVERSAL RUBBER CONE, OR USING ONE OF THE
THREADED CAPS, CONNECTING THEM TO FITTING N°. 7. (FIGURES 1-2)
4. CHECK THAT TAP N°. 3 IS OPEN AND THAT TAP N°. 6 IS CLOSED. (FIGURE 3)
5. CONNECT THE AIR LINE TO FITTING N°. 4.
6. SWITCH BUTTON N°. 5 TO "ON", TO LET ALL THE AIR OUT. (FIGURE 4)
7. CLOSE TAP N°. 3 WHEN THE PRESSURE REACHES 0.8 bar.
8. SWITCH BUTTON N°. 5 TO "OFF".
COOLANT FILLING
1. CONNECT HOSE N°. 10 TO FITTING N°. 8.
2. CLOSE TAP N°. 3 AND VISUALLY CHECK THE FILLING OF THE COOLANT HOSE.
3. OPEN TAP N°. 6 TO ALLOW COOLANT INTAKE. (FIGURE 5)
4. THE OPERATION IS COMPLETED WHEN THE NEEDLE OF THE INSTRUMENT IS RESET TO "ZERO".
NB: CHECK WHETHER THE RADIATOR HAS BEEN THOROUGHLY FILLED WITH THE COOLANT.
OTHERWISE, FILL UP MANUALLY.