Checking And Calibrating X And Y Axes - Wacker HAL 300 Manual De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Wacker HAL 300
4.3

Checking and Calibrating X and Y Axes

4.3.1
4.3.2
4.3.3
4.3.4
4.3.5
4.3.6
4.3.7
4.3.8
wc_tx000806gb.fm
All manuals and user guides at all-guides.com
Place the laser on a flat surface or tripod 100 ft. (30 m) away from a
wall. If too bright to see the beam, use a detector with a pole or grade
rod.
Position so that -X is facing the wall (this is the side of the laser with
the On/Off key).
Use the sighting groove on top of the instrument for alignment.
Hold ROTATION key. While holding, momentarily press the ON key.
Look for
Y LED flashes, then X LED flashes. Release rotation key.
X LED will blink rapidly, indicating leveling. When the LED blinks
slowly, the laser is ready to verify X axis calibration.
To rotate laser beam: Press SCAN key on the remote (or press the
rotation key on the laser keypad).
Check X calibration:
4.3.4.1
With detector, mark center of the beam (-X).
4.3.4.2
Rotate laser 180° so +X is facing wall or pole.
4.3.4.3
With detector, mark center of the beam (+X).
4.3.4.4
At 100 ft., the marks should be no more than 1/4" apart. (At
30 m, no more than 6 mm apart.)
If the marks are close enough, X axis is within calibration; proceed to
Step 6.
If the marks are not close enough, the laser must be calibrated to bring
the beam to the center of the two X marks. Use the (^) or (v) ARROW
keys on the remote (preferred) or laser keypad to move beam up or
down to the center.
Note: With the arrow keys, make small inputs: one click, two clicks,
three clicks, etc. Do NOT hold key down.
After calibrating X, check Y. Rotate laser 90° degrees so that -Y is
facing the wall (this is the side of the laser with the keypad).
Select the Y axis by pressing the double arrow key ( >>l ) on the remote
(or the HI key on the laser keypad).
Look for
Y LED blinking rapidly, indicating leveling. When the LED blinks
slowly, the laser is ready to verify Y axis calibration.
Check Y calibration:
4.3.8.1
With detector, mark center of the beam (-Y).
4.3.8.2
Rotate laser 180° so +X is facing wall or pole.
EN-20
Maintenance

Publicidad

Tabla de contenido
loading

Productos relacionados para Wacker HAL 300

Este manual también es adecuado para:

Hal 300-230v

Tabla de contenido