Button Functions - CAME CP Serie Manual Para El Instalador

Interfaz lan
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
After making the access, if the page is not interacted with, the session
SIFLAN
will remain active for three minutes, after which it will automatically
close and the access page will again be displayed.
The "Settings" key at the bottom of the page lets you access the
changes page to modify the device settings:
Modify the device's network configuration as required. To allow access to the
device over the internet, you will need to set up the gateway IP-address field so
that it points to the network gateway and consequently configure the gateway
itself. Finally, change the predefined web installer password (field: Web Technical
Password).
SEDPLANWS/SEDPLAN
SIFLAN/SSIP
.
At this point, configure the control unit. From local keypad 1
NOTES:
The webpage in which the keyboard is displayed can be integrated with the security
alarm control unit, by using the displayed keyboard or by using the following
computer keyboard keys:
0..9 and 0..9 number keypad →keys 0...9
a, +, left arrow key → key A
SIFLAN/SSIP
b, -, right arrow key → key B
c, Up arrow → key C
d, Down arrow →key D
SIFLAN
SEND →* key
ESC / CANC → # key
The DEL key on the computer keyboard is intercepted by the browser to load the
previously viewed page.

BUTTON FUNCTIONS

Function of the S1 key forSSIP
Keep pressed (5 secs) → will initialise the device at default parameters (keep pressed until
the yellow communication LED stays on).
Function of the S1 key forSIFLAN
Quick press →reset device
Keep pressed (5 secs)→will initialised the device at default parameters (keep pressed until the three red-green-yellow communication
LEDs flash three times simultaneously).
Key at the bottom of the page ( onlyfor SIFLAN) :
"Back/Indietro": returns to the keypad webpage, without saving changes
"Save/Salva": saves any changes and starts the device
"Initialize/Inizializza": restores the devices predefined parameters (just like keeping the reset button on the device pressed for an extended
time).
"Log out/Esci": closes the session. If the browser is shut down without exiting the session, the session will stay active for three minutes,
during which any other access will be refused. If the control unit is left in user menu or technical menu, the control unit will automatically
exit the menu after one minute.
The language of the device will align with that of the control unit after:
- resetting the control unit:
- exiting the technical menu after entering the settings menu SIFLAN/SSIP .

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Security siflanSecurity ssip

Tabla de contenido