Operation Mode; User Mode - Airzone ZBS Manual Del Usuario

Ocultar thumbs Ver también para ZBS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation Mode

To change the Operation Mode, press the Operation Mode icon and select the mode:
Cool. In this mode, the conditioning unit will start a cooling cycle any time that any zone
is in cool demand (T
Heat. Enables the heating cycle whenever a zone is in heating demand (T
Auto. The Auto mode allows automatic switching between cool and heat, depending on
the global demand.
Dry. Only available in direct expansion systems. The system works in dry mode, refreshing
the zone (reducing the humidity) when any of the zones is generating demand (T
T
).
room
Note: Dry mode decreases humidity in the room by entering the dehumidification cooling
cycle.
Emergency Heat. This mode activates the Auxiliary Heat to provide heated air in case of
a mechanical failure in the system.
Note: This mode is only visible when the installation includes an auxiliary heating device.

User Mode

To change the User Mode, press the User Mode icon and select the desired mode:
Comfort. Default and standard user mode. The desired set point temperature can be
selected using the predefined temperature ranges.
Eco. The range of available set point temperatures adapts for getting a more efficient
operation.
Night time. The system automatically changes the set point temperature 0.5º C/1º F every
30 minutes in up to 4 increments of 2º C/4º F in 2 hours. When cooling, the system
increases the set point temperature; when heating, the system decreases the set point
temperature.
< T
). It enables to activate the heat supply function.
Set-Point
room
EN
> T
).
Set-Point
room
EN
FR
<
Set-Point
PT
DE
9
IT

Publicidad

Tabla de contenido
loading

Tabla de contenido