Panasonic WH-SDC03H3E5-1 Instrucciones De Funcionamiento página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
Menus
For installer
Menu
16
Default Setting
Setting Options / Display
Control pattern Advanced parallel
Heat
Selection of the tank
• "Heat" implies Buffer Tank and "DHW" implies
Domestic Hot Water Tank�
Control pattern Advanced parallel Heat Yes
• Buffer Tank is activated only after selecting
"Yes"�
Set the temperature
-8 °C
threshold to start the
bivalent heat source�
Delay timer to start the
0:30
bivalent heat source
(in hour and minutes)�
Set the temperature
-2 °C
threshold to stop the
bivalent heat source�
Delay timer to stop the
0:30
bivalent heat source
(in hour and minutes)�
Control pattern Advanced parallel DHW Yes
• DHW Tank is activated only after selecting
"Yes"�
Delay timer to start the
0:30
bivalent heat source
(in hour and minutes)�