Changing the Tool
Before any work on the machine itself, pull
the mains plug.
Wear protective gloves.
The saw blades used must correspond to
the characteristic data in these operating
instructions.
Use only saw blades with an allowable
speed matching at least the no-load speed
of the machine.
To tighten or loosen clamping bolt 6, either place
the saw blade on wood or lock the mounting
flange 9 with open-end wrench, size 41 mm.
Removing
Pivot back the swinging protective guard 4 and
hold firmly.
Using the Allen key 17 unscrew the clamping
bolt 6.
Remove clamping flange 5.
Remove the saw blade.
Mounting
Clean the saw blade and all the clamping parts to
be assembled.
Place the saw blade onto the mounting flange 9.
Assemble the clamping bolt 6 and clamping
flange 5.
Tighten using the Allen key 17.
Take care that the mounting positions of the
mounting flange 9 and clamping flange 5
are correct.
When mounting, take care that the cutting
direction of the teeth (direction of the arrow
on the saw blade) and the direction of rota-
tion arrow on the protective guard agree.
5
6
Sawdust Vacuuming
External Vacuuming
The dust chute 2 for dust collection fits the Bosch
35 mm hose system.
The machine can be plugged directly into the re-
ceptacle of a Bosch general-purpose vac with re-
mote starting control. The vac starts automatically
when the machine is switched on.
The vacuum cleaner must be suitable for the ma-
terial to be worked.
When vacuuming dry dust that is especially detri-
mental to health or carcinogenic, use a special
vacuum cleaner.
Bosch offers suitable vacuum cleaners for all ma-
terials to be worked.
Internal Vacuuming
For small jobs use the dust sack (accessories).
Mount the dust extraction adapter 2 to the dust
extraction opening 1. Insert the dust sack sleeve
into the dust extraction opening 1. Empty the dust
sack in time, so that the dust extraction is always
optimal.
8
7
9
The dust that is produced while
working can be detrimental to
health, inflammable or explosive.
Suitable safety measures are re-
quired.
Examples: Some dusts are re-
garded as carcinogenic. Use
suitable
dust-/chip
extraction
and wear a dust mask.