2.3 Environment
Warning! The product may not be exposed to moisture, condensing humidity,
contamination or dust.
WORKING TEMPERATURE
1.
STORAGE TEMPERATURE
2.
IP LEVEL
3.
3. PRODUCT OVERVIEW
CTRL INDICATOR
LED Indicates Digital
Controller connection
IN - DIGITAL
CONTROLLER INPUT
Input for Digital Controller
or in-line connectable ballast
OUT - LINK TO THE
NEXT BALLAST
Line out to next
connectable ballast
4. INSTALLATION
PLEASE COMPLY WITH LOCAL INSTALLATION REGULATIONS.
1.
Keep distance between your ballasts to insure a free air flow. Keep at least 5 cm distance between
individual ballasts. Mount ballasts on a non-combustible material and not on the floor where it could come
into contact with water or nutrients. These ballasts are for indoor use only. Optimum operating conditions
should not exceed: Max Ambient Temperature: 40C, Min Ambient Temperature: -20C. Max Humidity: 90%
2.
Carefully screw a compatible MH, HPS or Dual Spectrum lamp into the reflector, ensuring full contact.
Ensure ballast wattage matches lamp wattage. Make sure you have dry hands when locating the lamp.
We recommend you use a cloth when handling the lamp. Connect reflector cable to ballast output cable
ensuring a good connection.
3.
If you are not controlling the ballast externally with the Lumatek Digital Lighting Controller;
Plug your Lumatek ballast into a lighting contactor relay. To protect timer against the inductive load of the
ballast, we recommend plugging the ballast 240V power plug into a lighting contactor relay, which can then
be plugged into a timer and then into the mains supply. Do not plug ballast into domestic timer directly. Switch
on. If unit fails to ignite lamp; switch off at mains, remove lamp and repeat steps 2. and 3. above. Otherwise
contact your retailer.
If you are controlling the ballast externally with the Lumatek Digital Lighting Controller;
Ensure ballast is connected to Lumatek digital controller (see controller instructions). Connect ballast to mains
and switch on mains power.
This ballast uses a fault indicator LED to help identify problems;
If your ballast is being controlled by an external digital controller, please refer to the controller manual for
guidance.
Specifications
-20℃~ +40℃
-40℃~ +70℃
IP20
MANUAL
DIMMING KNOB
For standard use without
Lumatek Digital Controller