4. Where not to install the device
In an enclosed space (for example in a cupboard or behind a curtain).
Where it can be obstructed (for example by furniture).
Directly above a sink.
Next to a door or window.
Next to an extractor fan.
Next to an air vent or other similar ventilation openings.
In an area where the temperature may drop below -5°C or exceed 50°C.
Where dirt and dust may block the sensor.
In a damp or humid location.
In the immediate vicinity of a cooking appliance.
5. Mounting
(see page 2)
The CO
Monitor comes with screws and wall plugs for mounting on the wall. Remove the CO
2
from the mounting plate, turn (11) counterclockwise approximate 15°. Use the mounting plate to mark
the drill holes. After drilling, place the dowels in the holes and then screw down the mounting plate with
the screws. Switch on the back-up battery (10), fully charged is approximate 12 hours usage without
adapter connection. Connect the adapter to the CO
Monitor on the mounting plate and turn (12) approximate 15° clockwise.
6. Status indicator - Green / Yellow / Red
When CO
concentration is ≤1000PPM, the status indicator turns green.
2
When CO
concentration is 1000PPM ~ 1500 PPM, the status indicator turns yellow.
2