INTRODUCTION
These instructions and the information contained within the product datasheet must be read thoroughly as they contain valuable information
gained by extensive experience. It is very important that all instructions are carefully followed and where appropriate they should be incorporated
into the end user's standard operating procedures. Use of this product in a manner other than in accordance with Pall's current
recommendations may lead to injury or loss. Pall cannot accept liability for such injury or loss.
SPECIFICATIONS
The maximum working pressure and temperature can vary between capsule assembly types or filter media. Please check the datasheet and
labelling for details, or contact Pall or your local distributor. Short term exposure to pressurized air or nitrogen above the maximum working
pressure is allowable for integrity testing of filter capsule assemblies.
Please consult Pall for details. Operation outside the specifications and with fluids incompatible with construction materials may cause personal
injury and result in damage to the equipment.
Incompatible fluids are fluids that chemically attack, soften, stress, attack or adversely affect the materials of construction.
Please refer to Pall for exact limits.
STATIC ELECTRICITY
WARNING! USE OF THE PALL INDUSTRIAL CAPSULE ASSEMBLIES WITH LOW CONDUCTIVITY LIQUIDS CAN RESULT IN THE
ACCUMULATION OF A STATIC CHARGE. THIS HAZARD WILL BE INTERMITTENT AND WILL DEPEND ON ATMOSPHERIC CONDITIONS SUCH
AS HUMIDITY
For guidance, low conductivity liquids may be considered as those with a conductivity below 50 pS/m. Aqueous solutions with a conductivity
above 50 pS/m.
But care should always be taken to prevent the likelihood of static damage.
When static charge is accumulated, both the filter capsule and the liquid leaving the assembly will retain the charge.
Pipe work upstream and downstream of the filter assembly should be of conductive materials and grounded.
Care should be taken when removing the filter capsule from pipe work to avoid static discharge. It may be necessary to allow time for the static
charge to dissipate before removal. Internal static discharge within a charged filter capsule may result in damage to the filter media. For further
information please contact Pall.
RECEIPT OF EQUIPMENT
WARNING! PLEASE CHECK THE PRODUCT LABEL PRIOR TO USE TO ENSURE PRODUCT PART NUMBERS CORRESPOND TO THE
APPLICATION
(a) Unpack carefully and check items against invoice
(b) Store the filter capsule assembly in clean, dry conditions between 0 °C and 30 °C (32 °F and 86 °F) without exposure to irradiation
sources like direct sunlight, and wherever practical in the packaging as delivered. Ensure that pre-wet capsules are stored above 0 °C
(32 °F) to avoid freezing.
(c) DO NOT remove the filter capsule from packaging until just before installation.
(d) Check that the product, bag or packaging is undamaged as received. Damaged items should not be used.
(e) Filter capsule assemblies may contain filter medium that is supplied pre-wet and such items must be used immediately after removal from
the packaging.
INSTALLATION AND OPERATION
WARNING! PLEASE ENSURE YOU CHECK THE SYSTEM FOR LEAKS PRIOR TO INTRODUCTION OF PROCESS FLUID
Installation
Install the capsule assembly in-line using compatible connections. Ensure that it is installed in the correct orientation for flow from the inlet to the
outlet and is adequately supported. Most capsules have the flow direction indicated on the filter assembly.
(a) If valves and inlet/outlet connectors are protected by plastic caps, the caps should be removed prior to use.
(b) For capsules suitable for vent applications, flow can be in either direction, but must be maintained within the specifications.
(c) Liquid filter capsule assemblies can be positioned in any orientation, providing that effective venting of the filter can be carried out before
and during operation and in accordance with the flow direction arrow annotated on the filter capsule.
UR610/690 Series
UR6 1 0/ 6 9 0 Ser vice Instr uctio ns
INTROD
Estas in
adquirid
incorpo
da Pall
ESPEC
A temp
rótulos
nitrogên
Consult
causar
Fluidos
fabricaç
Consult
ELETRI
AVISO!
ESTÁTI
Como r
com co
Quando
A tubul
Deve-s
para qu
danos a
RECEB
AVISO!
APLICA
(a) Des
(b) Arm
(c) NÃ
(d) Ver
(e) As
INSTAL
AVISO!
Instala
M&ESI610ENa
Instale
líquido
própria
(a) Se
(b) Par
fon
car
ime
esp

Publicidad

loading

Resumen de contenidos para Pall UR610 Serie

  • Página 1 The maximum working pressure and temperature can vary between capsule assembly types or filter media. Please check the datasheet and A temp labelling for details, or contact Pall or your local distributor. Short term exposure to pressurized air or nitrogen above the maximum working rótulos pressure is allowable for integrity testing of filter capsule assemblies.
  • Página 2 1/2”-13UNC threads (for A and D ports) or M12x1.75- Please contact Pall or an approved distributor if further information 6H threads (for C and F ports) are provided at the inlet is required.
  • Página 3: Routine Maintenance

    A dirty system can quickly plug a new filter element, especially 4 amps at 250 VAC with Pall high efficiency filter media. It may require one or two 0.25 amp resistive at 220 VDC initial element changes to stabilize element life. If element 0.50 amp resistive at 110 VDC...
  • Página 4 Seller. All claims must be accompanied by full particulars, including ELEMENT. system operating conditions, if applicable. ONLY USE GENUINE PALL REPLACEMENT FILTER Seller shall not be liable for any product altered outside of the Seller’s ELEMENTS. USE OF SUBSTITUTE ELEMENTS MAY factory except by Seller or Seller’s authorized distributor, and then,...
  • Página 5: Parts List

    UR610/690 UR610/690 Series R E T U R N L I N E F I L T E R S s e r v i c e i n s t r u c t i o n s Parts List List Description Quantity...
  • Página 6 UR610/690 UR610/690 Series R E T U R N L I N E F I L T E R S s e r v i c e i n s t r u c t i o n s Figure 2 R610 Filter assy view 9 or 11 6 or 8...
  • Página 7 UH319 UR610/690 UH319 Series UR610/690 Series H I G H P R E S S U R E F I LT E R S s e r v i c e i n s t r u c t i o n s R E T U R N L I N E F I L T E R S s e r v i c e i n s t r u c t i o n s Figure 3...
  • Página 8 Visit us on the Web at www.pall.com Pall Corporation has offices and plants throughout the world. For Pall representatives in your area, please go to www.pall.com/contact Because of technological developments related to the products, systems, and/or services described herein, the data and procedures are subject to change without notice.

Este manual también es adecuado para:

Ur690 serie