Descargar Imprimir esta página

JetAir SURI BL/A/60 Instrucción Sobre La Instalación Y El Uso página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
EN - Instruction on mounting and use
Closely follow the instructions set out in this manual. All responsibility,
for any eventual inconveniences, damages or fires caused by not
complying with the instructions in this manual, is declined. The hood is
conceived for the suction of cooking fumes and steam and is destined
only for domestic use.
The hood can look different to that illustrated in the drawings in this
booklet. The instructions for use, maintenance and installation,
however, remain the same.
!
It is important to conserve this booklet for consultation at any moment.
In the case of sale, cession or move, make sure it is together with the
product.
!
Read the instructions carefully: there is important information about
installation, use and safety.
!
Do not carry out electrical or mechanical variations on the product or
on the discharge conduits.
!
Before proceeding with the installation of the appliance verify that
there are no damaged all components. Otherwise contact your dealer
and do not proceed with the installation.
Note: the elements marked with the symbol "(*)" are optional accessories
supplied only with some models or elements to purchase, not supplied.
Caution
WARNING! Do not connect the appliance to the mains until the
installation is fully complete.
Before any cleaning or maintenance operation, disconnect hood from the
mains by removing the plug or disconnecting the mains electrical supply.
Always wear work gloves for all installation and maintenance operations.
The appliance is not intended for use by children or persons with impaired
physical, sensorial or mental faculties, or if lacking in experience or
knowledge, unless they are under supervision or have been trained in the
use of the appliance by a person responsible for their safety.
This appliance is designed to be operated by adults, children should be
monitored to ensure that they do not play with the appliance.
This appliance is designed to be operated by adults. Children should not
be allowed to tamper with the controls or play with the appliance.
Never use the hood without effectively mounted grating!
The hood must NEVER be used as a support surface unless specifically
indicated.
The premises where the appliance is installed must be sufficiently
ventilated, when the kitchen hood is used together with other gas
combustion devices or other fuels.
The ducting system for this appliance must not be connected to any
existing ventilation system which is being used for any other purpose such
as discharging exhaust fumes from appliances burning gas or other fuels.
The flaming of foods beneath the hood itself is severely prohibited.
The use of exposed flames is detrimental to the filters and may cause a
fire risk, and must therefore be avoided in all circumstances.
Any frying must be done with care in order to make sure that the oil does
not overheat and ignite.
Accessible parts of the hood may became hot when used with cooking
appliance.
With regards to the technical and safety measures to be adopted for fume
discharging it is important to closely follow the regulations provided by the
local authorities.
The hood must be regularly cleaned on both the inside and outside (AT
LEAST ONCE A MONTH).
This must be completed in accordance with the maintenance instructions
provided in this manual). Failure to follow the instructions provided in this
user guide regarding the cleaning of the hood and filters will lead to the
risk of fires.
Do not use or leave the hood without the lamp correctly mounted due to
the possible risk of electric shocks.
We will not accept any responsibility for any faults, damage or fires
caused to the appliance as a result of the non-observance of the
instructions included in this manual.
This appliance is marked according to the European directive 2002/96/EC
on Waste Electrical and Electronic Equipment (WEEE). By ensuring this
product is disposed of correctly, you will help prevent potential negative
consequences for the environment and human health, which could
otherwise be caused by inappropriate waste handling of this product.
The symbol
on the product, or on the documents accompanying the
product, indicates that this appliance may not be treated as household
waste. Instead it should be taken to the appropriate collection point for the
recycling of electrical and electronic equipment. Disposal must be carried
out in accordance with local environmental regulations for waste disposal.
For further detailed information regarding the process, collection and
recycling of this product, please contact the appropriate department of
your local authorities or the local department for household waste or the
shop where you purchased this product.
Additional Installation Specifications:
Use only the fixing screws supplied with the product for installation or, if
not supplied, purchase the correct screws type.
Use the correct length for the screws which are identified in the
Installation Guide.
In case of doubt, consult an authorised service assistance centre or
similar qualified person.
WARNING! Failure to install the screws or fixing device in accordance
with these instructions may result in electrical hazards.
Use
The hood is designed to be used either for exhausting or filter version.
Ducting version
In this case the fumes are conveyed outside of the building by means of a
special pipe connected with the connection ring located on top of the hood.
Attention! The exhausting pipe is not supplied and must be purchased
apart.
Diameter of the exhausting pipe must be equal to that of the connection
ring.
In the horizontal runs the exhausting pipe must be slightly slanted (about
10°) and directed upwards to vent the air easily from the room to the
outside.
Attention! If the hood is supplied with active charcoal filter, then it must be
removed.
Connect the hood and discharge holes on the walls with a diameter
equivalent to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will
cause a diminution of the suction performance and a drastic increase in
noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum elbow angle:
90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct as smooth as possible inside.
!
The duct must be made of certified material.
Filter version
One active charcoal filter is needed for this and can be obtained from your
usual retailer.
The filter removes the grease and smells from the extracted air before
sending it back into the room through the upper outlet grid.
Installation
The minimum distance between the supporting surface for the cooking
equipment on the hob and the lowest part of the range hood must be not
less than 50cm from electric cookers and 65cm from gas or mixed
cookers.
If the instructions for installation for the gas hob specify a greater distance,
this must be adhered to.
Using a electric impact drill to bore 6 holes with 8mm-diameter and 40mm
depth on appropriate locarions on mounting wall according to drill
template. Burying expand nails and fixing hook plate and chimney hook
on the wall with wood screw. Check whether hook plate and chimney fixed
plate are uneven after finishing installation (Fig. 1-5).
The range hood is intended to be installed over a hob having 6 heating
elements.
Clean Stainless Steel Panel
Fig.9
When removing the oil filter, use both hands to hold the bottom of the oil
filter and then pull it out, to make the snap-in mechanism which is used to
fix the oil filter can be separated from the oil filter. The oil filter can be
removed after it is turned to the top surface level. During daily cleaning
process, the outer surface of the oil filter can be cleaned using soft gauze,
neutral or slightly alkaline detergent, and warm water.
Electrical connection
The mains power supply must correspond to the rating indicated on the
plate situated inside the hood. If provided with a plug connect the hood to
a socket in compliance with current regulations and positioned in an
accessible area, after installation. If it not fitted with a plug (direct mains
connection) or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with standards
which assures the complete disconnection of the mains under conditions
relating to over-current category III, in accordance with installation
instructions.
Warning! Before re-connecting the hood circuit to the mains supply and

Publicidad

loading

Este manual también es adecuado para:

Ariel wh/a/60