If the display shows BAT.CHARGED (Is tested battery charged?), please press ▲\▼
11.
key to answer YES or NO then press "ENTER" to the next step. (BT300 tester will
judge the tested battery status & decide to show out Step11.)
12.
When the test is complete, the LCD shows the actual voltage and actual CCA. Press
the ▲\▼ key to see the SOC (STATE OF CHARGE) , SOH (STATE OF HEALTH) or mΩ
(Internal Resistance).
One of following five results will be displayed:
OK
The battery is good & capable
of holding a charge.
OK
The battery is good but needs
RECHARGE
to be charged.
RECHARGE
Battery is discharged. The
RETEST
battery condition cannot be
determined until it is fully
charged. Recharge & re-test
the battery. If reading is the
same, the battery should be
replaced immediately.
BAD
- The battery can not hold a
charge. It should be replaced
immediately. Or
- The battery has at least one
cell short circuit. It should be
replaced immediately.
ERROR
- The clamps are not
connected properly. Please
check if the clamps are
connected properly. Or
- The tested battery is bigger
than maximum testing CCA
capacity.
13.
Press <<ENTER>> return to Step 3 or remove the test clamps from the battery posts
after completion of testing.
All selected data will be memorized after test, including battery type, battery CCA standard,
capacity of CCA, etc.
HI or LO mΩ means it is out of range.
- GB.6-V1 -
6