MENU ITEM 3 - CHANNEL MUTE (Mute)
Mute channels A to D.
Briefly press the MENU dial to access the device settings selection menu and then turn the dial to select menu item 3. Mute off. Now press
one of the buttons SELECT A to D and make the desired setting in the relevant channel by turning the dial (Mute On/Mute Off). Press the dial to
activate. In order to select and edit one of the other channels A to D, turn the dial to move the arrow to the desired channel, press the dial and
make the settings as described above. In order to return to the main display, briefly press the EXIT / LOCK button, several times if necessary.
MENU ITEM 4 - POLARITY
Set the polarity of channels A to D.
Briefly press the MENU dial to access the device settings selection menu and then turn the dial to select menu item 4. Pol. off. Press one of
the buttons SELECT A to D and make the desired setting in the relevant channel by turning the dial (Normal (+) = polarity not inverted, Invert
(-) = polarity inverted). Press the dial to activate. In order to select and edit one of the other channels A to D, turn the dial to move the arrow
to the desired channel, press the dial and make the settings as described above. In order to return to the main display, briefly press the EXIT
/ LOCK button, several times if necessary.
MENU ITEM 5 - DELAY
Set the channel delay for channels A to D.
Briefly press the MENU dial to access the device settings selection menu and then turn the dial to select menu item 5. Delay off. Now press
one of the buttons SELECT A to D and make the desired setting in the relevant channel by turning the dial (delay is displayed in metres and
milliseconds, delay up to max. 138 ms, 25°C = reference temperature – setting for reference temperature via LD Systems OCS software).
Press the dial to activate. In order to select and edit one of the other channels A to D, turn the dial to move the arrow to the desired channel,
press the dial and make the settings as described above. In order to return to the main display, briefly press the EXIT / LOCK button, several
times if necessary.
MENU ITEM 6 - PARAMETRIC EQUALIZER
12-band parametric equalizer for channels A to D.
Briefly press the MENU dial to access the device settings selection menu and then turn the dial to select menu item 6. PEQ off. Press one
of the buttons SELECT A to D to make the desired setting in the relevant channel. Turn the dial to select the desired equalizer band 1 to 12
in order to edit, then confirm by pressing the dial (Band 1 = Low Shelf, Band 2–11 = Bell, Band 12 = High Shelf). Now you can edit the filter
quality (Q), frequency (Freq.) and gain (Gain) of the selected band according to preference by moving the arrow to the relevant position,
pressing the dial to confirm and making settings by turning the dial. Press the dial to activate. In order to select and edit one of the other
channels A to D, press EXIT once, move the arrow to the desired channel, press the dial and make the settings as described above. In order
to return to the main display, briefly press the EXIT / LOCK button, several times if necessary.