Greenlee TPIR-J Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation
1.
See the instruction manual supplied with the multimeter (purchased separately).
2.
See Typical Measurements for specific measuring instructions.
3.
Connect the TPIR-J or TPIR-K to the input terminals of the multimeter. Set the multimeter
to read temperature.
4.
Turn the unit on.
5.
Test the unit on an object with a known temperature.
• If the unit does not function as expected on an object of known temperature, replace
the battery.
• If the unit still does not function as expected, send the unit to Greenlee for repair.
6.
Take the reading from the object being measured.
Notes:
• Do not touch or hold by the front cone of sensor. Temperature readings can be affected by
heat from hands.
• If the object or target temperature is above or below the specified range or battery power is
low, the meter will alternate between displaying a reading and a display code. See Display
Code Descriptions for more information.
Display Code Descriptions
Display Code*
270 °C (518 °F)
or –30 °C (–22 °F)
280 °C (536 °F)
or –45 °C (–49 °F)
–60 °C (–76 °F)
Ambient
temperature
* Values may vary ±5 degrees depending on meter accuracy.
6
All manuals and user guides at all-guides.com
Description
Target temperature is
over or under range
Ambient operating temperature
is over or under range
Battery is low
Unit in warm-up or
sleep mode
Action
Select target within unit's
specifications
Allow unit to stabilize in its
ambient operating range
Replace battery
Restart unit by turning unit
to OFF and then ON.

Publicidad