TROUBLESHOOTING

Problem
"ADD " indicator is
on.
"FULL
" indicator is
on.
Ice cubes stick
together.
Ice making cycle is
normal but no ice
formed.
www.newair.com
Possible Causes
Lack of Water.
Ice is full in basket.
The ice making cycle is
too long.
Water temperature in
inner tank is too low.
Room temperature or
water temperature in
inner tank is too high.
Refrigerant in cooling
system leaks.
Pipe in the cooling
system is blocked.
Solution
Stop the ice maker, fill
water, and press
button again to
restart the unit.
Remove ice from ice
basket. Continuously
press
button for
5 seconds, the unit
could make ice 10 cycles
even though "FULL
indicator is on.
Stop the ice maker, and
restart it when the ice
blocks melt. Select the
small size ice cube
selection.
Replace the water.
Temperature of water
recommended at 40 F-
90 F
The room temperature
should be 50 F-10 F,
water temperature
should be 40 F-90 F
Verify by a qualified
technician.
Verify by a qualified
technician.
EN
"