require special attention.
• The anti-grease BAFFLE
which offers improved performance with respect to the classic
aluminium filters. Its structure means it is able to retain grease
particles, thereby reducing noise to a minimum. It should be
washed regularly every 15 to 30 days in order to prevent the
oil from leaking out; this may be done by hand or using the
dishwasher.
- After a few washes, colour alterations may occur. This does
not give the right to claim their replacement.
• The active carbon filters are used to purify the air that is
sent back into the room and its function is to mitigate the
unpleasant odours produced by cooking.
- The non-regenerable active carbon filters (cod. 901589) must
be replaced at least every 4 months. The saturation of the active
charcoal depends on the more or less prolonged use of the
appliance, on the type of kitchen and on the frequency with
which anti-grease filter is cleaned.
- Regenerable active charcoal filters (cod. 901590) must be
washed by hand, with non abrasive neutral detergents, or
in the dishwasher at a maximum temperature of 65°C (the
washing cycle must be complete without dishware). Remove
excess water without damaging the filter, remove the plastic
parts, and let the filter dry in the oven for at least 15 minutes
approximately at a maximum temperature of 100°C. To keep
the regenerable charcoal filter functioning efficient this ope-
ration must be repeated every 2 months. These should be
replaced at least every 3 years or when the filter is damaged.
• Before remounting the anti-grease filters and the rege-
nerable active charcoal filters it is important that they are
completely dry.
• Clean the hood frequently, both internally and externally,
using a cloth dampened with denatured alcohol or neutral
liquid detergents that are non abrasive.
• The lighting .system is designed for use during cooking
and not for the prolonged general lighting of the room. The
prolonged use of the lighting system significantly decreases
the average duration of the bulbs.
• Attention: the non compliance with the hood cleaning
warnings and with the replacement and cleaning of the filters
entails risk of fires. One therefore recommends keeping to the
suggested instructions.
• Replacing LED lamps (Fig.8)
The intervention of a specialised technician is necessary to
replace them.
• Commands luminous (Fig.9) the key symbols are explained
below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes (*)
Your appliance has the INTENSIVE speed function, from speed
THREE, press key E for 2 seconds and it will be activated for 6
minutes after which it will return to the previously set speed.
When the function is active the LED flashes. To interrupt it
before the 10 minutes have elapsed, press key E again.
• Function Clean air
By pressing key F for two seconds (with the hood switched off)
the "clean air" function is activated. This function switches the
appliance on for ten minutes every hour at the first speed. As
soon as this function is activated the motor starts up at the
first speed for ten minutes. During this time key F and key
filter: This is a suction system
C must flash at the same time. After ten minutes the motor
switches off and the LED of key F remains switched on with
a fixed light until the motor starts up again at the first speed
after fifty minutes and keys F and C start to flash again for ten
minutes and so on. By pressing any key for the exclusion of
the hood light the hood will return immediately to its normal
functioning (e.g. if key D is pressed the "clean air" function is
deactivated and the motor moves to the 2nd speed straight
away. By pressing key B the function is deactivated).
• Function Timer
(*) The "AUTOMATIC STOP TIMER" delays stopping of the
hood, which will continue functioning for 15 minutes at the
operating speed set at the time this function is activated.
• Anti-grease/active charcoal filters saturation:
- When the A key flashes with a 2 second frequency the anti-
grease filters must be washed.
- When the A key flashes with a 0.5 second frequency the
active carbon filters must be replaced or washed depending
on the type of filter.
Once the clean filter has been put back one must reset the
electronic memory by pressing the A key for approximately 5
seconds until it stops flashing.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR EVENTUAL DAMAGES CAUSED BY BREACHING THE
ABOVE WARNINGS.
- 15 -