The blender will automatically turn off after 10 minutes. To reset the blender
for the next operation, turn the speed dial back to the OFF position.
• Preset Program Key: To use the preset programs, the blender should first
be in Stand-By Mode, then select and rotate the Speed Dial from the OFF
position to the desired preset program setting and when finished press the
ON/OFF button.
To stop the blender during operation of one of the programs, press the ON/
OFF button to stop the blender. After operation of the preset program, the
blender reverts to stand-by mode.
Icon
LID, MEASURING CUP
• Insert the measuring cup in the lid by aligning the two tabs in the slots on the
lid and twisting to lock. Then push the lid onto the blender jug to close it. To
open the lid, pull the flap up.
BLENDER · BPF-1200S
Function
Operation cycle
Soup
Increases to Speed 7 in 7 sec, then
increases to Speed H in 3 sec, and
keeps at this speed until finish.
Total duration is 8 minutes.
Every start-up is soft-start.
Vegetables
Speed H 30s, stop 2s;
Speed 6 10s, stop 2s;
Speed H 60s, stop 2s;
Speed 6 10s, finish.
Total operation is 1m 56s.
Every start-up is soft-start.
Smoothie
Soft start to Speed H for 8s, and
stop for 2s. Repeats the cycle until
the total operation time is 30s.
Every start-up is soft-start.