Checking the welding
Operation: working with the hand inductor
Fig. 2
Please note that the underside of the inductor must be positioned parallel to
the top face of the plate!
Technical data
Induction generator:
Workable temperature range: -5 °C to +50 °C
Electrical connection:
Power consumption:
Frequency:
Tool dimensions:
Height:
Depth:
Weight:
If the correct parameters have been selected for the welding
and the recommended test weld has been successful with
positive results, and the instructions in the operating instructions
have been followed, no further checks of the operation are
necessary.
If you are not sure whether certain joints have already been
welded, SFS intec recommends using the suction pad provided
or a commercially available suction device to carry out a test. Try
to lift the roofing membrane at the point in question. If that is
possible, the joint is still open and requires welding.
Alternatively it is also possible to carry out welds with the hand
inductor (available as an option). This may be appropriate on roof
upstands, around rooflights, on shed roofs etc.
The hand inductor is controlled via the main tool and automatically
adopts all functions and settings from it!
1. Unplug the inductor from the main tool
2. Plug the hand inductor into the main tool (see Fig. 2).
3. Carry out calibration as described in the "Calibration" section.
4. For further steps, see "Operation: welding" section.
110V / 230 V
1500 Watt
50 Hz / 60 Hz
approx. 1100 mm (assembled)
600 mm
18.5 Kg (complete)
Dimensions of transport box:
L/W/H: 770 x 560 x 500 mm
Weight: 19.5 Kg