Page 4
ENGLISH
1.6
Materials Needed For Installation
The following items are needed and are to be supplied
by the installer for all heat pump installations:
1.
Plumbing connections (2").
2.
Level surface for proper drainage. (See equipment
pad for pitch requirements)
3.
Suitable electrical supply line. See rating plate on
unit for electrical specifications. A junction box is
not needed at the heat pump; connections are made
inside of the heat pump electrical compartment.
Conduit may be attached directly to the heat pump
jacket.
NOTE Flex conduit is recommended for connecting
the electrical supply wires to the heat pump so
that the front panel may be removed easily for
servicing.
4.
Electric cutout switch that will interrupt all power
to the unit. This switch must be within line of sight
of the heat pump.
5.
Watertight conduit to run the electrical supply line.
MODEL
JRT2000R
JRT2500R
JRT3000R
A
Figure 1.
Jandy JRT Heat Pumps Dimensions
Jandy
®
JRT Series Heat Pumps
B. Water Inlet
A
C. Water Outlet
42"
45"
|
Installation and Operation Manual
1.7
Specifications
Suitable for indoor and outdoor use. Clearances shown
in Table 2 must be adhered to.
Water Pipe/Heater Connection
Plastic
Flow Rate
Maximum
Optimum
Minimum
Operating Water
Temperature
Minimum
Maximum
Maximum Working
Water Pressure
Electrical Supply
Voltage Requirements
1-Phase
Maximum Working
Refrigerant Pressure
Dimensions
See Figure 1 for heat pump's dimensions and for
dimensions to critical connections.
Technical Specifications
See Table 1 for the Jandy JRT heat pump technical
specifications.
32"
B
C
3"
11.50"
10"
2" PVC (Unions included)
70 gpm (265 lpm)
JRT2000R= 42 gpm (159 lpm),
JRT2500R = 48 gpm (182 lpm),
JRT3000R = 57 gpm (216 lpm)
JRT2000R/2500R = 20 gpm (76 lpm)
JRT3000R= 30 gpm (114 lpm)
32° F (0° C)
104° F (40° C)
75 psi
230 VAC 60Hz
600 PSI
32"