9.4 PANEL FILTER ELEMENT

Annual replacement of the panel filter element is recommended. To
replace the panel filter element, remove the panel filter by pulling up and
out of its slots, then fit the new element in.

9.5 PRE-FILTERS AND POST-FILTERS

WARNING
a
Depressurize the system before disassembling filters. Failure to do so
may result in injury or death.
Filter elements should be changed as indicated on the pressure
differential gauge. Change carbon elements when hydrocarbons are
first detected downstream or every six months, whichever comes first.
Certain filters contain multiple elements. When replacing filter elements,
all elements should be replaced simultaneously. Mixing new and old
elements can result in reduced air quality.
9.5.1

THREADED FILTERS:

NO-LOSS DRAIN VALVE
All manuals and user guides at all-guides.com
9.0 SCHEDULED MAINTENANCE
2
4
5
6
4
Nirvana Cycling Refrigerated Dryer Models 200-400
http://air.irco.com
Assembly Control unit onto service unit:
Check if service unit (3) matches control unit (1) (type designation and
colour of latching hook)
1
Check if sensor tube plate (5) with contact springs (4)
is clean, dry and free from foreign matter.
2
Insert sensor (2) into sensor tube plate (5).
3
Fit latching hook (6) of control unit (1) into sensor tube
plate (5).
4
Press control unit (1) against service unit (3) and snap
into place
• Open drain isolation ball valve. Press drain test button to verify proper
drain operation.