6.0 SAFETY AND OPERATION PRECAUTIONS
Air Under Pressure Will Cause
Injury, Death Or Property Damage.
• Do Not Exceed Pressure Rating.
• Relieve Press. Before Servicing.
• Do Not Modify/Repair/Rework
ASME Coded Pressure Vessels
As Insurance Rating Affected.
READ TECHNICAL MANUAL
Removing fuses will not disconnect
power from dryer. Always disconnect
power from ALL sources before
performing service.
READ TECHNICAL MANUAL
FAN MAY AUTOMATICALLY
START AT ANY TIME
This unit is charged with
refrigerant under high pressure.
4
All manuals and user guides at all-guides.com
ELECTRICAL CONNECTION BOX
CONTAINS HIGH VOLTAGE
• Turn Off Power And Lock Out At ALL Sources Before Opening
To Perform Service.
• Remote Alarm Contact Wiring Has Control Power From
Separate Source.
READ TECHNICAL MANUAL
ELECTRICAL CONNECTION BOX
•
All Customer Connections To Be Made At This Location.
•
See Terminal Connection Diagrams, below.
•
Be Certain To Follow All NEC, State, Local and Other Applicable
Codes During Installation.
100-125VAC / 1 PH
1
2
GRN
G
INCOMING
FACTORY
3
LINE VOLTAGE
WIRING
WHT
N
100-125VAC
4
1PH/50-60HZ
BLK
L1
(BY OTHERS)
5
(REFER TO UNIT
NAMEPLATE FOR
6
POWER
REQUIREMENTS)
Alternate three-phase wiring may be black / black / black.
Nirvana Cycling Refrigerated Dryer Models 200-400
http://air.irco.com
200-240VAC / 1 PH
1
2
GRN
G
INCOMING
FACTORY
3
FACTORY
LINE VOLTAGE
WIRING
200-240VAC
4
1PH/50-60HZ
BLK
L1
(BY OTHERS)
5
(REFER TO UNIT
RED
L2
NAMEPLATE FOR
6
POWER
REQUIREMENTS)
Air Under Pressure Will Cause
Injury, Death Or Property Damage.
• Relieve Press. Before Servicing.
• Condensate Drain Discharges
Under Pressure.
• Drain Requires Periodic
Cleaning (Service).
READ TECHNICAL MANUAL
HIGH VOLTAGE
200-575VAC / 3 PH
1
2
GRN
G
INCOMING
3
LINE VOLTAGE
WIRING
RED
L1
200-575VAC
4
3PH/50-60HZ
WHT
L2
(BY OTHERS)
5
(REFER TO UNIT
BLK
L3
NAMEPLATE FOR
6
POWER
REQUIREMENTS)