Emerson White Rodgers 1F89-0211 Manual Del Usuario
Emerson White Rodgers 1F89-0211 Manual Del Usuario

Emerson White Rodgers 1F89-0211 Manual Del Usuario

Ocultar thumbs Ver también para White Rodgers 1F89-0211:

Publicidad

Enlaces rápidos

Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
YOUR THERMOSTAT REPLACES
Description
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (with 1 Aux. or Emergency Heat Stage)
Standard Heat & Cooling Systems
Two Stage Heat & Two Stage Cool
Standard Heat Only Systems
Millivolt Heat Only Systems - Floor or Wall Furnaces
Standard Central Air Conditioning
Gas or Oil Heat
Electric Furnace
Hydronic (Hot Water) Zone Heat – 2 Wires
Hydronic (Hot Water) Zone Heat – 3 Wires
SPECIFICATIONS
Electrical Rating:
Battery Power ................................................. mV to 30 VAC, 50/60 Hz or DC
Input-Hardwire ................................................ 20 to 30 VAC
Terminal Load ........................................................ 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range ...................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage) ...................................... Heat 0.8°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient ................................................. 32° to +105°F (0° to +41°C)
Operating Humidity ................................................ 90% non-condensing max.
Shipping Temperature Range ................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ......................................... 3-3/4"H x 4-3/4"W x 1-1/2"D
PRECAUTIONS
WARNING
!
Do not use on circuits exceeding specifi ed voltage.
Higher voltage will damage control and could cause
shock or fi re hazard.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a fi re hazard.
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
All manuals and user guides at all-guides.com
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
No
www.white-rodgers.com
1
Blue 2" Heat Pump Thermostat
Heat Pump or Single Stage
Installation and Operating Instructions
Model
1F89-0211
1F89-0211 Thermostat
Index
Installation
Wiring Diagrams
Thermostat Quick Reference
Installer Confi guration Menu
Operation
Troubleshooting
Programming Choices
Non-Programmable
Page
2
3
4
4
6
7
PART NO. 37-6997C
Replaces 37-6997B
0932

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Emerson White Rodgers 1F89-0211

  • Página 1 All manuals and user guides at all-guides.com Blue 2” Heat Pump Thermostat Heat Pump or Single Stage Installation and Operating Instructions Save these instructions for future use! Model Programming Choices FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS 1F89-0211 Non-Programmable CONTROL COULD CAUSE PERSONAL INJURY AND/OR...
  • Página 2 All manuals and user guides at all-guides.com INSTALLATION Battery Door REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall.
  • Página 3: Wiring Diagrams

    All manuals and user guides at all-guides.com WIRING DIAGRAMS THERMOSTAT SYSTEM SYSTEM Changeover MONITOR Relay* SWITCH Aux/Emergency Optional Compressor Relay Heat Relay Contactor (Stage 2) 24 VAC 120 VAC Neutral * Changeover Relay is energized in COOL when O/B switch is in the “O” position Changeover Relay is energized in HEAT when O/B switch is in the “B”...
  • Página 4: Thermostat Quick Reference

    All manuals and user guides at all-guides.com THERMOSTAT QUICK REFERENCE Before you begin programming your thermostat, you should be 10 “Service” indicates a diagnostic fault in the heating/ familiar with its features and with the display and the location cooling system. It does not indicate a fault in the and operation of the thermostat buttons and switches (see fi...
  • Página 5 All manuals and user guides at all-guides.com INSTALLER/CONFIGURATION MENU Confi guration Menu Menu Press Displayed Comments Press Reference (Factory to select Number Default) from listed op- tions Select Cool Savings Feature On or OFF (OFF) 1, 2, 3, 4, 5, 6 If CS selected On, selects Cool Savings value CR HE-PU Select Adjustable Anticipation, cycle rate, Heat...
  • Página 6: Check Thermostat Operation

    All manuals and user guides at all-guides.com OPERATION Emergency System CHECK THERMOSTAT OPERATION EMER bypasses the Heat Pump to use the heat source wired If at any time during testing your system does not operate to terminal W2 on the thermostat. EMER is typically used when properly, contact a qualifi...
  • Página 7: Troubleshooting

    All manuals and user guides at all-guides.com TROUBLESHOOTING Reset Operation If a voltage spike or static discharge blanks out the display or for approximately 10 seconds until the display goes blank. If causes erratic thermostat operation, you may need to reset the thermostat has power, has been reset and still does not the thermostat.
  • Página 8 The key to reducing energy costs and minimizing Auxiliary or Second Stage is to set the thermostat to the lowest comfortable heating temperature. Homeowner Help Line: 1-800-284-2925 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. www.white-rodgers.com...
  • Página 9 All manuals and user guides at all-guides.com...
  • Página 10 All manuals and user guides at all-guides.com...
  • Página 11 All manuals and user guides at all-guides.com...
  • Página 12 All manuals and user guides at all-guides.com...
  • Página 13 All manuals and user guides at all-guides.com...
  • Página 14 All manuals and user guides at all-guides.com...
  • Página 15 All manuals and user guides at all-guides.com...
  • Página 16 All manuals and user guides at all-guides.com...

Tabla de contenido