General Instructions
Nozzle Installation:
Note: Nozzles should be installed
fi rst.
If installing Rigid Gooseneck
1. Apply tefl on tape or pipe joint
compound to threaded end of no.9.
2. Tighten no.9 fi rmly by hand into
no.2.
9
2
If installing Swivel Nozzle:
3. Insert no.9 or no.10 into no.2 and
rotate to front of sink.
4. Tighten no.16 fi rmly with a
wrench.
9 or 10
11, 12,
14, 15
For swivel repair or replacement of
(o-ring) no.15 and (sleeves) no.14:
5. Insert one no.14 onto no.11. Install
no.15 on no.11 and lubricate liberally
with provided no.17. Install second
no.14 onto no.11. (See Enlarged
View)
16
2
4
11
14
Enlarged View
Faucet Installation:
6. Shut off water supply and drain
lines. Drill (2) two holes, approxi-
mately 1-1/4" [3 cm] diameter in
wall with 8" [20 cm]centers, where
you are installing no.1.
8"
[20cm]
7. Apply tefl on tape or pipe joint
compound to water supply lines.
8. Connect no.2 to water supply
lines by attaching no.3 with eccen-
tric centers onto nipple supplied
by others and tighten no.3 against
wall. Make sure no.4 is in place. Nut
behind wall to be supplied by oth-
ers. Trim supply lines if necessary.
wall
4
2
3
water supply line
(supplied by others)
9. Turn on water supply and check
for leaks.
15
nut