7. FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE

WARNING: A SPARK NEAR THE
BATTERY MAY CAUSE A BATTERY
EXPLOSION. TO REDUCE THE RISK OF
A SPARK NEAR THE BATTERY:
7.1 Check polarity of battery posts. POSITIVE
(POS, P, +) battery post usually has a larger
diameter than NEGATIVE (NEG, N, –) post.
7.2 Attach at least a 24-inch-long 6-gauge
(AWG) insulated battery cable to
NEGATIVE (NEG, N, –) battery post.
7.3 Connect POSITIVE (RED) charger clip to
POSITIVE (POS, P, +) post of battery.
7.4 Position yourself and free end of cable as
far away from battery as possible – then

8. GROUNDING AND AC POWER CORD CONNECTIONS

8.1 This battery charger is for use on a
nominal 120 volt circuit and has a
grounded plug. The charger must be
grounded, to reduce the risk of electric
shock. The plug must be plugged into
an outlet that is properly installed and
grounded in accordance with all local
codes and ordinances. The plug pins
must fit the receptacle (outlet). Do not use
with an ungrounded system.
8.2 DANGER: Never alter the AC cord or
plug provided – if it does not fit the outlet,
have a proper grounded outlet installed
by a qualified electrician. An improper
connection can result in a risk of an
electric shock or electrocution.
NOTE: Pursuant to Canadian
Regulations, use of an adapter plug
is not allowed in Canada. Use of an
adapter plug in the United States is not
recommended and should not be used.
9. ASSEMBLY INSTRUCTIONS
9.1 Remove all cord wraps and uncoil the cables prior to using the battery charger.

10. CONTROL PANEL

CHARGE RATE SELECTOR SWITCH
Use this switch to set the maximum
charge rate to one of the following:
2A Slow Charge – For small batteries,
such as those commonly used in garden
tractors, snowmobiles and motorcycles.
6A or 10A Fast Charge – For automotive,
marine and deep-cycle batteries.
Not intended for industrial applications.
30A Boost – This setting may be used for
a quick charge, prior to using the engine
start setting. Do not use this setting to
fully charge your battery.
connect NEGATIVE (BLACK) charger clip
to free end of cable.
7.5 Do not face battery when making final
connection.
7.6 When disconnecting charger, always do
so in reverse sequence of connecting
procedure and break first connection
while as far away from battery as
practical.
7.7 A marine (boat) battery must be removed
and charged on shore. To charge it on
board requires equipment specially
designed for marine use.
8.3 USING AN EXTENSION CORD
The use of an extension cord is not
recommended. If you must use an
extension cord, follow these guidelines:
• Pins on plug of extension cord must be
the same number, size, and shape as
those of plug on charger.
• Ensure that the extension cord is
properly wired and in good electrical
condition.
• Wire size must be large enough for
the AC ampere rating of charger, as
specified:
Length of cord (feet)
AWG* size of cord
*AWG-American Wire Gauge
Engine Start – Provides additional amps
for cranking an engine with a weak or run-
down battery. Always use in combination
with a battery.
AMMETER
The ammeter gives a reading of the Amp
draw by the battery from the charger.
When a fully discharged battery is
connected to the charger, the ammeter
will read the maximum output rating
of the charger, either 2, 6 or 10 Amps,
depending on the Amp selection. The
charge current will gradually taper down
• 4 •
25
50
100
150
18
16
14
14