Maintenance instructions:
Clean lint screen after each cycle.
I
Removing accumulated lint (disconnect dryer from electricity
I
and gas supplies before starting this task):
From inside the dryer cabinet:
•
Lint should be removed every 2 years or more often, depending
on dryer usage. Cleaning should be done by a qualified person.
From the exhaust vent:
•
Lint should be removed every 2 years, or more often,
depending on dryer usage.
If you need further assistance, you can contact the dealer/
distributor where the dryer was purchased.
When you call, you will need the dryer model number and serial
number. Both numbers can be found on the serial-rating plate
located on your dryer.
TECHNICAL SPECIFICATIONS - GAS DRYER
220-240V~50Hz 1ph 3A max. IP24 Clothes capacity: 9.0 kg max. Sound pressure level, Lpa: 58 dBA
(uncertainty, Kpa: +/–10 dBA) Total mass: 68 kg max.
Factory set for NATURAL GAS: Injector size: 2.2 mm Heat input gross: 5.9 kW
European Country:
European Gas Category:
Gas Flow Rate:
Supply Pressure (G20):
Factory Adjusted Pressure:
With LP Gas Conversion Kit: Injector size: 1.25 mm Heat input gross: 6.4 kW
European Country:
European Gas Category:
Butane Supply Pressure (G30):
Adjusted Pressure:
Propane Supply Pressure (G31):
Adjusted Pressure:
With France/Belgium NATURAL GAS conversion kit: Injector size: 1.65 mm Heat input gross: 5.9 kW
European Country:
European Gas Category:
Supply Pressure (G20):
Supply Pressure (G25):
Adjusted Pressure:
NOTE: Conversion kit: From Natural Gas to LP Gas: Whirlpool Part No. W10233219.
Conversion kit: From Natural Gas to Natural Gas - France/Belgium: Whirlpool Part No. W10184947.
Manufacturer: Whirlpool Corporation, Benton Harbor, Michigan 49022, USA.
EU representatives: Whirlpool UK Ltd, Croydon, CR9 4RY, UK.
10
MAINTENANCE INSTRUCTIONS
ASSISTANCE OR SERVICE
CH, CZ, CY, ES, GB, GR, HR,
CH, CZ, CY, ES, GB, GR, HR,
& Bauknecht Hausgeräte GmbH, D-73614 Schorndorf, Germany
If dryer does not operate, check the following:
Electric supply is connected.
I
Circuit breaker is not tripped or fuse is not blown.
I
Door is closed. Listen closely to hear door switches activate.
I
Selected cycle button has been pressed firmly and display
I
shows cycle time.
Check that gas supply shutoff valves are set in open position.
I
For Warranty Terms and Conditions, contact the dealer/distributor.
IE, IT, PT, SI, SK, TR
II 2H3+
3
0.562703 m
/hr
20 mbar
7.4 mbar
IE, IT, PT, SI, SK, TR
II 2H3+
28-30 mbar
N/A
37 mbar
N/A
FR, BE
20 mbar
25 mbar
CY, CZ, DK, EE, FI, GR, HU, IT,
NO, RO, SE, SK, TR
II 2H3B/P
0.562703 m
20 mbar
7.4 mbar
CY, CZ, DK, EE, FI, GR, HU, IT,
NO, RO, SE, SK, TR
II 2H3B/P
30 mbar
N/A
30 mbar
N/A
I 2E+
N/A
3
/hr