Briteq LDP-COBWASH WW Serie Manual De Instrucciones página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
OPERATING INSTRUCTIONS
Note: when the projector is switched on the display shows "UPDATE WAIT ..." This message informs you
that IF you want to upgrade the firmware, you should do it while this message is shown on the display. For
normal use you can ignore this message completely.
A. Standalone 1unit:
 Just connect the projector to the mains.
 Select menu option "MASTER" to set the desired light output.
 Refer to chapter HOW TO SETUP to learn how to set the other menu options.
B. Two or more units in master/slave setup:
 Connect the units together. Refer to the chapter "electrical installation" to learn how to do this.
 Select menu option "MASTER" to set the desired light output on the master (the first projector in the
DMX chain)
 Set all the other projectors in SLAVE mode
 The projectors will now follow the settings of the master projector so they all work synchronously.
C. Controlled by universal DMX-controller:
 Connect all units together. Refer to the chapter "Electrical installation for two or more units in DMX-
mode" to learn how to do this (don't forget to address all units properly!)
 Connect all units to the mains and turn on the DMX controller.
Since each unit has its own DMX-address, you can control them individually. Remember that each unit
can use a different number DMX-channels, depending on the DMX-mode you have selected in the
menu. See the different DMX charts below:
DMX Chart for the 1 channel DMX-Mode
Channel:
Value:
1
000-255
DMX Chart for the 2 channel DMX-Mode
Channel:
Value:
1
000-255
000-005
2
006-255
MAINTENANCE
 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
Attention: We strongly recommend internal cleaning to be carried out by qualified technician!
BRITEQ
®
Function:
Master dimmer (0-100%)
Function:
Master dimmer (0-100%)
Open
Increasing strobe speed
9/50
OPERATION MANUAL
No strobe
006 = slow 255 = fast
LDP-COBWASH 50 + 100 (WW/CW)
Remarks:
Remarks:

Publicidad

Tabla de contenido
loading

Tabla de contenido