Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pressu-
res.
Installation Instructions
•
The fitting must be installed, flushed and tested after
the valid norms.
•
If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart®
(flow limiter) located behind the aerator can be
removed.
•
Hansgrohe mixers can be used together with hydrau-
lically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
Technical Data
This mixer series-produced with EcoSmart®
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
4
English
Symbol description
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
Assembly see page 32
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 31. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Dimensions (see page 34+35)
Flow diagram
(see page 34+35)
with EcoSmart®
without EcoSmart®
Spare parts (see page 37)
Operation (see page36)
Cleaning
Cleaning recommendations, see enclosed
brochure.
Special accessories
special tool order as an extra
Installation kit order as an extra
Test certificate (see page 38)