Insertion Of Batteries; Device Description - LaserLiner ActiveFinder One Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
• The device measures the presence of electrostatic fields of sufficient strength.
If the field strength is too low voltage may still be applied although no
warning signal is given. The following list of factors that influence the field
strength does not claim to be complete: shielding, cable insulation (type,
thickness), measurement distance, insulation between user and earth, special
socket designs, condition of tester and of batteries.
Additional information on use
Observe the technical safety regulations for working on electrical systems,
especially: 1. Safely isolating from power supply, 2. Securing to prevent system
being switched on again, 3. Checking zero potential, two-pole, 4. Earthing and
short-circuiting, 5. Securing and covering adjacent live components.
Safety instructions
Dealing with electromagnetic interference
• The measuring device complies with safety and electromagnetic compatibility
regulations and limits in accordance with the Low Voltage Directive 2
014/35/EU and electromagnetic compatibility regulations in accordance
with the EMC Directive 2014/30/EU.
• Local operating restrictions – for example, in hospitals, aircraft, petrol
stations or in the vicinity of people with pacemakers – may apply.
Electronic devices can potentially cause hazards or interference or
be subject to hazards or interference.
Symbols
Fig. B: Warning about hazardous electrical voltage: Unprotected live components
inside the device housing are capable of posing a risk of electric shock.
Fig. C: Protection class II: The test device has reinforced or double insulation.
Fig. D: Overvoltage category III: Equipment in fixed installations and for
applications where specific requirements with regard to the reliability and
availability of equipment have to be met, e.g. circuit-breakers in fixed
installations and devices used in industrial applications which are permanently
connected to the fixed installation.
1

Insertion of batteries

Open the battery compartment and insert battery according to the symbols.
Be sure to pay attention to polarity.

Device description

1
Detector tip with LED
indicator (green/red) /
status indicator
!
Before using the device, you should always test it on a main circuit you
know to be operational within the specified voltage range.
2
ON / OFF
(see Fig. A)
08
EN
(see Fig. E)
(see Fig. F)
2
ON/OFF
3
Pocket clip
4
Battery compartment

Publicidad

Tabla de contenido
loading