Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.

Safety notes

• Installation is only possible in frost-free rooms.
• The transformer is only suitable for indoor use.
• In the case of damage to the external transformer
connection cable, this must be replaced by the manufacturer
or his customer service department or an equally qualified
person, in order to prevent a hazard.
• For cleaning purposes, the transformer plug must not be
directly or indirectly sprayed with water.
• The voltage supply must be separately switchable.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.

Technical data

• Flow pressure
min. 0.5 bar - recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure exceeds 5 bar, a pressure-reducing
valve must be fitted.
Avoid major pressure differences between
hot and cold water supply.
• Flow rate at 3 bar flow pressure:
• Temperature:
Hot water supply
Recommended (energy saving):
• Supply voltage (transformer 230 V AC/12 V AC):
• Power consumption:
• Automatic safety shut-off
(factory setting):
• Run-on time (factory setting):
• Reception range with Kodak Gray Card,
grey side, 8 x 10", landscape, 5cm below
the spout (factory setting):
• Type of protection: - Fitting
- Transformer
• Water connection
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Special accessory
• Infrared remote control (Prod. no. 36 407) for changing the
factory settings and selecting special functions.
3
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Flush pipes thoroughly before and after installation
(observe EN 806).
Fitting
Refer to the dimensional drawings on fold-out page I.
Lift rod (A) must be inserted into the mixer body during
installation, see fold-out page II, Fig. [2].
Fasten fitting to wash basin, see Figs. [1] to [4].
Connection, see Fig.5
The cold water supply must be connected on the right, hot
water supply on the left.
Open hot and cold water supply and check connections
for watertightness.
max. 10 bar
Connecting the voltage supply
16 bar
Connect control electronics with plug-in connector (D) to
transformer (E), see Fig. [6].
Connect voltage supply via transformer (E).
Setting temperature limiter
approx. 6 l/min
1. Remove screw (F), see Fig. [7].
2. Turn mixer lever (G) clockwise until the desired maximum
max. 70 °C
temperature is reached.
60 °C
3. Detach mixer lever (G), see Fig. [8].
230 V
4. Detach stop ring (I) and reattach with notch (I1) pointing
3.2 VA
vertically upwards.
5. Turn mixer spindle (H) anti-clockwise to the stop.
60 s
6. Attach mixer lever (G) in horizontal position and fasten with
1 s
screw (F).
Operation
approx. 15cm
IP 59 K
The infrared electronics emit invisible, pulsed light.
The infrared-electronics are adjusted so that water flow is
IP 44
initiated when the hands approach the vicinity of the spout.
cold - right
hot - left
When the hands are withdrawn from the vicinity of the spout,
water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s (factory setting) of continuous detection of an object,
the infrared electronics automatically stop the water flow.
Automatic flushing (factory setting: not activated)
Automatic flushing serves to ensure water hygiene in the event
of long-term non-utilisation of the fitting. and activates water
flow for 1 - 10 minutes, 1 or 3 days after the last use.
Safety notes:
- Ensure free draining in the case of activated automatic
flushing.
- For automatic flushing of the hot and cold water lines, the
fitting must be in the mixed water setting.