4. REMOVAL FROM PACKAGING

Remove the machine from its packaging, taking
care to gather all the machine contents and docu-
ments.
WARNING!
ing the assembly should be done on a flat and
stable surface, with enough space for moving
the machine and its packaging, always making
use of suitable equipment.

5. PREPARING TO WORK

1. CHECKING THE MACHINE
WARNING!
not plugged into the mains socket.
Before starting work please:
– check that the mains frequency and voltage is
the same as the rating data on the "Identification
Plate" (see chap. 1 - 8.8).
– check that the switch lever and the safety switch
handle move freely without forcing and return au-
tomatically and rapidly back to their neutral po-
sition;
– check that the cooling air vents are not ob-
structed;
– check that the power cable and extension lead
are not damaged;
– check that handgrips and protection devices are
clean and dry, correctly mounted and well fas-
tened to the machine;
– check that the cutting devices and guards are not
damaged;
– check that the machine is not showing signs of
wear or damage due to knocks or other causes,
and carry out the necessary repairs.
Unpacking and complet-
Make sure the machine is
REMOVAL FROM PACKAGING / PREPARING TO WORK
Disposal of the packaging should be done in ac-
cordance with the local regulations in force.
2. ELECTRICAL CONNECTIONS
DANGER!
are not compatible.
– Always handle and connect electric cables
in dry conditions.
– Keep electric sockets or cables away from
wet and damp areas (e.g. puddles or wet
ground).
– Power the machine using a residual current
device (RCD Residual Current Device) with
max. 30 mA tripping current.
The quality of the extension leads must be no less
than H07RN-F or H07VV-F, with a minimum sec-
tion of 1.5 mm and a recommended maximum
length of 30 m.
To avoid overheating, do not keep the extension
lead rolled up during use.
DANGER!
tion of any electrical equipment to the mains of
a building must be installed by a qualified
electrician in conformity with the regulations in
force. Incorrect wiring can cause serious in-
jury and even death.
Electricity and moisture
The permanent connec-

Publicidad