Event Configuration; Quality Of Run Qor - CARLO GAVAZZI PD30ETB BP IO Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 129

2.5.7. Event configuration

Temperature events transmitted over the IO-Link interface are turned off by default in the sensor. If the user wants
to get information about critical temperatures detected in the sensor application, this parameter allows the
following 4 events to be enabled or disabled:
Temperature fault event: the sensor detects temperature outside the specified operating range.
Temperature over-run: the sensor detects temperatures higher than those set in the Temperature
Alarm threshold.
Temperature under-run: the sensor detects temperatures lower than those set in the Temperature
Alarm threshold.
Short-circuit: the sensor detects if the sensor output is short-circuited.

2.5.8. Quality of run QoR

The Quality of run informs the user about the actual sensor performance, evaluating the following parameters:
Maximum signal, Minimum signal, Hysteresis, SP and Safe Limits.
The value for QoR can vary from 0 ... 255 %.
The QoR value is updated for every detection cycle.
Examples of QoR is listed in the table below.
Quality of Run values
> 150%
100%
50%
0%
Explanation
Excellent sensing conditions, the sensor is not expected to require mainte-
nance in the near future.
Good sensing conditions, the sensor performs as well as when the setpoints
were taught or set-up manually with a safety margin of twice the
standard hysteresis.
• Long term reliability is expected under all environmental conditions.
• Maintenance is not expected to be required.
Average sensing conditions
• Due to environmental conditions, the reliability of the measurement values
is reduced and maintenance is required in order to improve the detection
behavior.
• If the environmental conditions remain stable, reliable detection can be
expected for the near future.
Unreliable sensing conditions, sensor does not work correctly, immediate
maintenance required.
Rev.00 - 06 .2021 | MAN PD30ETB IO-Link EN | © 2021 | CARLO GAVAZZI Industri
25

Publicidad

Tabla de contenido
loading

Tabla de contenido