2.6.6. Event configuration

Temperature events transmitted over the IO-Link interface are turned off by default in the sensor. If the user wants
to get information about critical temperatures detected in the sensor application, this parameter allows the
following 4 events to be enabled or disabled:
Temperature fault event: the sensor detects temperature outside the specified operating range.
Temperature over-run: the sensor detects temperatures higher than those set in the Temperature
Alarm threshold.
Temperature under-run: the sensor detects temperatures lower than those set in the Temperature
Alarm threshold.
Short-circuit: the sensor detects if the sensor output is short-circuited.

2.6.7. Quality of run QoR

The Quality of run informs the user about the actual sensor performance.
"Rating" is a summary of all QoR parameters. If conditions is good, object detected with a good signal, ambient
light low and sensor temperature is inside limits, then Rating is set to 100 (best score).
If Rating is < 100, the reason can be read in the other QoR parameters.
QoR parameters are listed in the table below.
Parameter
Rating
SignalLow
AmbientHigh
NoObjectDetected
TemperatureError

2.6.8. Quality of Teach QoT

The quality of teach value lets the user know how well the sensing conditions were during the teach procedure.
The quality of teach is a snapshot of the quality of run value "Rating"
22
Rev.00 - 01.2020 | LD30 IO-Link manual ENG | © 2020 | CARLO GAVAZZI Industri
Description
Sensor overall health check
[0-100] 100=best
0 = Signal OK
1 = Signal low
0 = ambient OK
1 = ambient high
0 = Object detected
1 = Object not detected
0 = Temperature OK
1 = Temperature outside min/max limits