Hayward AquaRite + Manual Del Usuario página 41

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
Setting the salt chlorination
1
OK
6
OK
3
Enter the Service menu from the configuration menu
4
Enter the password:
5
Choose the cell model corresponding to the one that is
installed.
6
Electrolysis: Electrolysis function programming.
7
Level: Chlorine production (gr/h) required.
Salt concentration
1
OK
Setting the pH correction time
1
OK
5
Page 17 of 23
2
7
8
Cover: Closed cover safety activation.
Reduction: % of chlorine production when the cover is
closed (20% by default).
9
Boost (Super Chlorination): Filtration and continuous
production of chlorine for 24 hours (maximum
production level).
Automatic return to the filtration and production mode
programmed after the 24 hours.
2
2
+
-
5
Check that the "Delay" parameter is correctly set to 2 minutes (time delay
after which the peristaltic pump starts up prior to injection).
Set the "Interval" parameter from 0 to 240 minutes according to the size
of your pool and the flow rate of the peristaltic pump (default setting
60 minutes).
Caution: if the interval is too long, your pool may not be protected
against acid overdoses and your equipment may be irreversibly
damaged. Too short an interval may trip unwanted AL3 alarms.
USE ONLY GENUINE REPLACEMENT PARTS
3
OK
8
3
3
AquaRite +
4
OK
9
OK
Note: the device can only control the operation of the
filtration pump if the pump is connected to the "Filter
Pump" relay.
10
During the boost period, redox control (option) can be
deactivated.
1
4
Salt concentration measurement.
2
Enter in the Salinity menu, use Enter to measure
the salt concentration for polarity 1, then for
polarity 2. This measurement can only be done
manually. It will have to be taken periodically.
3
Adjustment: Once the measurement has been
taken, you can adjust the salt level manually.
4
Display: Once the salt concentration has been
measured, it is displayed on the salt chlorination
screen and the main screen.
4
1
Setting the pH correction time.
The chemical parameters of the water must be set
manually before the device is started up. If these
adjustments are not made in advance, unwanted
AL3 alarms may be tripped.
2
Enter the password:
3
Select the "Dos. pumps" menu.
4
Select the "Pump times" menu.
Do not change the default values on the "Pump
alarm AL3" and "Tank signal" menus.
5
10
Rev. E

Publicidad

Tabla de contenido
loading

Tabla de contenido