Function
Auto Mode
Manual mode
Anti-leakage
Cut in
Cut out
Max pump on
(B) MODE selection button
Selectable modes:
1) AUTO_MODE;
2) MANUAL_MODE;
3) ANTI LEAKAGE;
4) CUT_IN;
5) CUT_OUT,
6) MAX_PUMP_ON;
To unlock the choice of function press "MODE" button for 5 seconds.
Press "MODE" to scroll through the various operating modes (AUTO_MODE or MANUAL_MODE) or parameters to be
modified (CUT IN and CUT OUT) or to enable certain functions (ANTI-LEAKAGE and MAX PUMP ON). While scrolling
through the modes, the LED of the function selected will flash. On returning to AUTO_MODE the active functions will be
highlighted by the relative LED lighting up with a steady light. See paragraph 2 (Description of the functions).
Indicators on "MODE"
AUTO MODE: the pump will work in automatic mode see 9.2.1
MANUAL MODE: the pump works in manual mode see 9.2.1, and the user can decide when to switch it on or off by acting
on the "SET" button. SET-ON switched On SET-OFF switched Off.
CUT-IN: pressure setting (always enabled) minimum pressure below which the pump is activated, can be set between 22
and 44 psi, factory setting 26 psi; the pump is activated even if the flow is less than a minimum value of 0.4 gpm, factory-
setting.
CUT-OUT: pressure setting (enabled) pressure above which the pump stops, the factory setting for "CUT-IN" + 1 Led, but
can be increased to 51 psi.
To enable it select the function by pressing "MODE" until the LED corresponding to CUT-OUT flashes then press SET to
select the required value, exit the setting by pressing "MODE". To disable the function, press "SET" until the light switches
on to indicate OFF.
Display configuration
ENGLISH
Set
ON: Enabled
OFF: Disabled
ON: Enabled
OFF: Disabled
ON: Enabled
OFF: Disabled
Increase/Decrease
Increase/Decrease
OFF: disabled
ON: enabled
OFF: disabled
5
Alarm Reset
Press SET
Press SET