„ SAFETY PRECAUTIONS

Read the labels on all LaMotte reagent containers prior to use. Some containers
include precautionary notices and first aid information. Certain reagents are
considered hazardous substances and are designated with a * in the instruction
manual. Safety Data Sheets (SDS) can be found at www.lamotte.com. Read the
SDS before using these reagents. Additional emergency information for all LaMotte
reagents is available 24 hours a day from the National Poison Control Center 1-800-
222-1222 or by contacting the 24 hour emergency line for ChemTel 1-800-255-
3924 (USA, Canada, Puerto Rico); locations outside the North American Continent
813-248-0585 (call collect). Be prepared to supply the name and four-digit
LaMotte code number found on the container label or at the top of the SDS or in the
contents list of the procedure. LaMotte reagents are registered with a computerized
poison control information system available to all local poison control centers.
Keep equipment and reagent chemicals out of the reach of young children.
Ensure that the protection provided by this equipment is not impaired. Do not intall
or use this equipment in a manner that is not indicated in this manual.

„ LIMITS OF LIABILITY

Under no circumstances shall LaMotte Company be liable for loss of life, property,
profits, or other damages incurred through the use or misuse of its products.
„ SPECIFICATIONS & RANGES
INSTRUMENT TYPE: Colorimeter
Readout
Wavelengths
Wavelength Accuracy
Readable Resolution
Wavelength Bandwidth
Photometric Range
Photometric Precision
Photometric Accuracy
Sample Chamber
Light Sources
Detectors
Modes
Pre-Programmed Tests
Languages
Temperature
Operation Humidity
Range
USB Port
Power Requirements
Battery
Electrical Rating
160 x 100 backlit LCD, 20 x 6 line graphical display
525 nm
±2% FS
Determined by reagent system
10 nm typical
–2 to +2 AU
± 0.001 AU at 1.0 AU
±0.005 AU at 1.0 AU
Accepts 25 mm diameter flat-bottomed test tubes
1 LEDs
1 silicon photodiode
Pre-programmed tests, absorbance, %T
YES, with automatic wavelength selection
English, Spanish, French, Portuguese, Italian, Chinese,
Japanese
Operation: 0-50 °C; Storage: -40-60 °C
0-90 % RH, non-condensing
Mini B
USB wall adapter, USB computer connection or lithium
ion rechargeable battery
Charge Life: Approximately 380 tests with backlight
on to 1000 tests with backlight off. Battery Life:
Approximately 500 charges.
Rated voltage (5V), Rated power of input current (1.0A)
at mini-USB input port