Classification in compliance with standard EN
60335-2-69 – Annexe AA
Vacuum cleaners for dust harmful to health are classified
according to the following dust classification:
1.
M (medium risk) suitable for separating dust with an
exposure limit value of over 0.1 mg/m
occupied volume;
2.
H (high risk) for separating all dust with an exposure limit
value lower than 0.1 mg/m
volume, including carcinogenic and pathogenic dusts.
Dust emissions into the environment
Indicative values of performance of:
•
versions for dust harmful to health
L: retains at least 99.1 % of particles measuring ≥ 3 μm;
M: retains at least 99.9 % of particles measuring ≥ 3 μm;
H: H14 class absolute filter in accordance with EN1822.
11/2008
, depending on the
3
, depending on the occupied
3
(Classes L - M - H):
General recommendations
DANGER !
Risk of fire outbreaks and explosions.
–
The vacuum cleaner can only be used when active
sources of ignition are not going to be vacuumed.
–
It is forbidden to vacuum the following materials:
burning materials (embers, hot ashes, lighted
cigarettes, etc.), flammable liquids, aggressive fuels
(e.g. gasoline, solvents, acids, alkaline solutions, etc.).
–
It is forbidden to vacuum the following materials:
explosive dust or dust liable to spontaneous ignition
(such as magnesium or aluminium dusts, etc.).
–
The vacuum cleaner is not suitable for vacuuming
explosive or similar substances, as established by the
laws governing explosive substances, particularly:
liquid fuels and mixtures of flammable dust and
liquids.
DANGER !
Emergency
If an emergency situation occurs:
–
filter breakage;
–
fire outbreak;
–
short-circuit;
–
engine seizing;
–
electric shock;
–
etc.;
turn off the vacuum cleaner, unplug it and ask for
assistance to be performed by qualified personnel.
Note
Check the place of work and substances tolerated for the
vacuum cleaner in Type 22 variant (version).
DANGER !
The vacuum cleaners must not be used or stored outdoors,
or in damp places.
The vacuum cleaner is not suitable for vacuuming liquids,
it can only be used to vacuum dry materials.
3
ATTIX 200
I
GB
F
D
E
C329