5. Commissioning, operation
Menu
Description
item
Colour settings (digital display)
COLR
CLRH
Upper limit value of the COLR function
Only active if COLR = rEd1, rEd2, Grn1
or Grn2
CLRL
Lower limit value of the COLR function
Only active if COLR = Grn1 or Grn2
RHL
Clear memory (min/max system pressure)
PAS
Password entry
TAG
Measuring instrument name (TAG)
WIKA operating instructions, model PSD-4-ECO
Parameter
rEd (0) = display always red
Grn (1) = display always green
rEd1 (2) = Red display, when the pressure value
is greater than/equal to the set value from CLRH
(otherwise green)
Grn1 (3) = Green display, when the pressure value
is greater than/equal to the set value from CLRH
(otherwise red)
rEd2 (4) = Red display, when the pressure value is
in the range of the set values of CLRL and CLRH
(otherwise green)
Grn2 (5) = Green display, when the pressure value
is in the range of the set values of CLRL and CLRH
(otherwise red)
Pressure value 0.25 ... 100 % of measuring range
0 ... (CLRH - 0.25 % of measuring range)
Yes / No
0000 = no password
Password input digit by digit
32 selectable characters (A-Z ‚0 ... 9; - ‚SPACE)
(2 spaces in sequence terminate the input and lead
to the deletion of this and the underlying characters)
Factory setting
rEd (0)
EN
Nominal pressure
Nominal pressure
- 10 %
0000
without
17