Type
Wetted part materials
Inlet connection
Outlet connection
Maximum working pressure
Compatible fluids
Flow
Viscosity range
Operating temperature
Precision
Pulse ratio
Maximum input voltage
Weight
Dimensions
Symptom
The meter is inaccurate.
Reduced flow.
The meter does not count.
4
SB 3107
Rev A 10/17
Balcrank™ Corporation · Weaverville, NC 28787 · 800-747-5300 · 800-763 0840 Fax · www.balcrank.com
Technical Specifications
Oval gear meter.
Acetal, Stainless Steel, Viton, CPVC.
1/2" BSP(F) and flange.
1/2" BSP(F) and flange.
435 psi (30 bar)
DEF (AdBlue
windshield washer.
0.26 -13.2 gpm (1 - 50 l/min.)
(depending on the viscosity of the fluid and temperature).
1 to 2000 cSt.
14 ºF to 140 ºF (-10 ºC to 60 ºC ).
±0.5%.
1211 ppg (320 ppl).
30 VDC.
1.1 lb (500 g).
3.6 in (93 mm)
Trouble-shooting
Possible cause
Erroneous calibration factor.
A fluid with very high or very low
viscosity is being used.
Very high or low fluid temperature.
The meter is working outside its
field of application (see technical
specifications).
Dirt in the measuring chamber.
Loose connections.
Faulty reed sensor.
Worn or damaged gears.
), glycol, coolant solutions, water,
®
Solution
Calibrate the management system
Calibrate the management system
Calibrate the management system
Restore the working conditions
(flow, viscosity, temperature...) to
those required by the meter.
Clean the measuring chamber.
Check connections.
Inform technical support.
Disassemble the meter and clean
or replace gears.
2.64 in (67 mm)