STRAINER MAINTENANCE
WARNING: Release all pressure within the system
!
and disconnect the air supply to the pump prior to
performing strainer replacement. Discharge pressure
operating the gun into an appropiate container and
open any bleeder-type air valves and fluid drain
valver in the system if necessary.
The gun can be provided with a strainer (optional). To
inspect
strainer
or
following procedure:
• Remove the cover (1) of the swivel and loosen the nut (2)
of the hose.
• Remove the o-ring (3), (4) and then the filter.
• Check the filter clean or replace as necessary.
• Place again the filter with the o-ring and install the hose
with the swivel cover.
TECHNICAL SPECIFICATIONS
Thread port
Moist parts materials
Meter type
Flow rate
Maximum pressure
Temperature range
Accuracy (oil)
Accuracy (coolant solutions)
Viscosity range
Display
Units
Batteries
Weight (with nozzle and batteries)
Dimensions (without nozzle tube)
12
SB3115
R. 07/22
Balcrank™ Corporation · Weaverville, NC 28787 · 800-747-5300 · 800-763 0840 Fax · www.balcrank.com
make
replacement
read
½" NPT
Acetal, stainless steel, NBR, aluminum, brass, zinc plated steel
Oval gear
0.25 - 7.5 US gal/min (1-30 l/min)
1450 psi (100 bar)
14 a 122 ºF (-10 a 50 ºC)
±0,5 %
±1 %
Up to 2000 mPa.s
LCD with double row digits
Litres, galons, quarts, pints
4 x AA 1.5V
4.6 lb (2.1 kg)
11.7" x 3.5" x 6.1" (297 x 89 x 155 mm) (length x width x height)
the
4
3
2
1