The remote control's range is too short.
The force setting has been altered, but no
difference is apparent.
The control board does not work any more using
the hand-held transmitter, only with the switch and
even then only as long as a button is pressed and
kept pressed.
Open with push-button (1) or CLOSE with push-
button (2)
The unit does not close automatically, it
OPENS automatically
Control board does not work with hand-held
transmitter
Gate can only be opened
The control board is not running
The wing does not open completely for the soft
stop
(Remote controlled) universal receiver does
not work
The installation of an external aerial is recommended as the controller with the short cable
aerial is located either behind the post or near ground level in most cases. The optimum
location of the aerial is as high as possible in all cases. An appropriate aerial with installation
kit can be obtained from Chamberlain as an accessory with the product ref. no. ANT4X-1EML.
Disconnect the controller from the power supply for a few seconds in order to activate the
control board's self-diagnosis functionality.
1.Dip switch setting not as desired
2.A safety photocell, a contact strip or the
stop disables the control board
3.Only one photocell was connected for
OPEN
Check setting of Dipswitch 7
1.Hand-held transmitter not
programmed
2.An photocell blocks
1.photocell blocks
2.Dip switch setting not as desired
No covered distance learned
1.Insufficient force in the event of high
wind loads
(entire gates)
2.Gate sluggish/heavy
Observe polarity (terminals 14/15)
D e c l a r a t i o n o f C o n f o r m i t y
Automatic Gate Opener Models HC100ML-2, HC500ML-2 Series
are in conformity to the applicable
sections of StandardsEN300220-3 • EN55014 • EN61000-3 • EN60555, EN60335-1 • ETS
300 683 • EN60335-1: 2002 • EN60335-2-103: 2003 • EN55014-1: 2000 + A1 + A2 •
EN55014-2: 2001 • EN61000-3-2: 2000 • EN61000-3-3: 1995 + A1 • EN 301 489-3,
V1.3.1 • EN 300 220-3 V1.1.1 • EN13241-1
per the provisions & all amendments
of the EU Directives .............................................2006/95/EC, 2004/108/EC, 1999/5/EG
D e c l a r a t i o n o f I n c o r p o r a t i o n
Automatic Gate Opener Models when installed and maintained according to all the
Manufacturer's instructions in combination with a Gate, which has also been installed and
maintained according to all the Manufacturer's instructions, meets the provisions of EU
Directive 89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
Chamberlain GmbH
D-66793 Saarwellingen
Mai, 2008
© Chamberlain GmbH 2008, all rights reserved
conforms to the above Directives and Standard
Harry Naumann Dipl.Ing.(FH)
Manager, Regulatory Affairs
1.Correction of the dip switch,
elimination of fault required. If the fault
cannot be repaired, it will be necessary
to "reset" and reprogram (see photocell)
2.At least one photocell must be
connected and activated for CLOSED
or OPEN & CLOSED.
Change setting of Dipswitch 7
1.Program hand-held transmitter
2.Check photocells
1.First limit switch gate OPEN
Function and connection of the limit
switches must be checked
2.Check dip switch
Learn covered distance.
See Initial operation
1.Reset force ( increase )
2.Improve ease of movement
3.Program control board without soft
stop
Swap "+" and "-" cables
s.
709442B