Operation (Continued)
2. Adjust paint tank regulator to 25
psi - 30 psi. More pressure is needed
on the material as the gun is moved
further above the tank. Normal
operating on the paint tank is 25
E
psi to 30 psi. When lower pressure
is needed, rotate the adjustment
N
counterclockwise until the desired
G
pressure setting is obtained. There is
L
no need to trigger the gun in order
I
to bleed off excess paint pressure.
S
Do not use over 50
H
psi in the tank.
The sprayer may now be used to apply
paint.
Maintenance
Always shut off air pressure
at source and bleed off all
pressure in paint tank by
gently pulling safety valve
ring before loosening knobs to remove
lid.
Paint Tank
®
CLEANING
IMPORTANT: It is very important that
the tank material hose and spray gun
be cleaned as soon as the spray job is
completed.
1. Shut off air tank at air pressure
regulator by turning adjusting screw
counterclockwise.
2. Gently pull safety valve ring to
purge air from tank.
3. Completely cover spray gun nozzle
with a soft rag and with air lines
pressurized, pull trigger of the gun.
This will force paint remaining in the
material hose back into the tank.
4. Remove tank lid and pour any
remaining paint back into original
containers for future use.
5. Using a clean, dry cloth, wipe inside
area of tank clean.
Never use this
paint tank
with materials which contain
trichloroethane, chlorinated
hydrocarbons, nitrohydrocarbons,
esters, amines, or organic compounds.
These materials will damage the gasket
between the paint tank and lid. A
damaged gasket may cause injury and
will reduce the efficiency of the paint
tank.
4
6. Pour about 1/2 gallon of paint
solvent into the tank. Use the correct
type of solvent for the paint being
used: mineral spirits for oil base
paint, lacquer thinner for lacquer
base paints, warm soap water for
Latex, etc.
7. Clamp lid onto tank and proceed to
spray the proper solvent through
spray gun and hose.
8. Following steps 1 through 9 in this
section, remove all thinner from
hose.
9. Clean lip of tank groove of paint
tank lid and gasket.
CLEANING THE SAFETY VALVE
Remove the safety valve and clean port
(orifice) periodically. Accumulations of
paint in the port can prevent proper
valve action. Do not disassemble valve
or change settings.
This component has
been factory
calibrated and sealed. Do not attempt
to disassemble safety valve or alter
calibration.
ROUTINE
Periodically inspect the tank for leaks
around the paint tank lid. If leakage
occurs, remove the pint tank lid and
clean lip of tank and groove in tank lid.
Replace gasket.
6Z899B