DUSI01EN - v6
3.5 HOW TO BLOCK THE PROGRAM SWITCH
To prevent undesired manipulation of the operating mode, the keypad can be locked by taking the following steps:
LOCK:
The door will work normally in the selected mode
but the operating mode can not be changed until
the selector is unlocked.
OPTIMA selector
Hold button 2 pressed, then press the
button
SMART selector
Hold button 2 (<) pressed, then press
button 4 (>).
A small lock will show in the display
3.6 OPENING FROM THE OUTSIDE WITH A KEY SWITCH (OPTIONAL)
When the door needs to be opened from the outside, even with it is in CLOSED mode, it is necessary to use the manusa
outside key switch.
The door will open automatically to allow entry, and then close and resume previous operating mode.
1
3.7 EMERGENCY STOP (OPTIONAL)
When operating in AUTOMATIC and EXIT ONLY modes, we can stop the door by activating an interlock button (emergency
stop).
If they are moving, the door leaves will stop and remain still.
To resume normal operation, the emergency stop button must be unlatched by pulling the button.
2
Activate
To open without power supply, refer to 4.4
Activate stop
UNLOCK:
The door will work normally in the selected mode
and anybody with access to the selector can
change the operating mode.
OPTIMA selector
Hold button 2 pressed, then press the
button
SMART selector
Hold button 4 (>) pressed, then press
button 2 (<). Four digits will appear on the
screen. Enter your PIN code by selecting
the digits with buttons 2 (<) or 4 (>) and
confirm with button 3.
Once the correct PIN has been entered,
the selector will be unlocked and the lock
will disappear from the screen.
Minimum time > 0,5 seconds
Resume normal operation
19
3
Remove